www.eurolite.de
29
Switching the Remote Control on and off
To set the remote control, press the button
MENU
until the display indicates “
rEno
“. Then press
ENTER
to
make your settings. Use the buttons ▲ and ▼ to deactivate the remote control (indication “
off
”) and to
reactivate it (indication “
on
”). Once again, press
ENTER
to confirm your settings.
Switching the Fluid Sensor on and off
To protect the pump, the machine uses a fluid sensor to test if there is smoke fluid in the tube. If the sensor
detects not enough fluid in the tube, the machine will enter a protection mode after about 20 seconds and
shuts the pump down. The display will start flashing.
To set the sensor, press the button
MENU
until the display indicates “
orL
”.Then press
ENTER
to make your
settings. Use the buttons ▲ and ▼ to deactivate the fluid sensor (indication “
off
”) and to reactivate it
(indication “
on
”). Once again, press
ENTER
to confirm your settings.
Note, however, that this sensor is a very important protection mechanism. For proper
operation, it should be activated.
Summary of Contents for NSF-350
Page 18: ...www eurolite de 18 KONFORMIT T...