30248000_V_1_1.DOC
13/15
installation material. If you lack these qualifications, do not attempt the installation yourself, but instead use a
professional structural rigger. Improper installation can result in bodily injury and.or damage to property.
The installation has to be attached out of the reach of people.
5.1 Installation on a trussing system
Caution:
Trussing installations may cause severe injuries when crashing down! If you have doubts
concerning the safety of a possible installation, do NOT install the trussing!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the
installation's weight.
For suspending on crossbeams, split boxes must always use a minimum of two hooks.
Attach the upper fixation of a C-hook to the crossbeam and tighten the fixation screw. Attach the Alubar to
the lower fixation of a C-hook and tighten the fixation screw.
Secure the suspended part with a safety-rope that can hold at least 12 times the weight of the installation.
You must only use safety-ropes with quick link with screw cap. Pull the safety-rope through the safety rope
hole and over the trussing system or a safe fixation spot. Insert the end in the quick link and tighten the
safety screw.
The trussing system must always be earthed!
5.2 Attachment
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
The device must only be installed absolutely planar at a vibration-free, oscilation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the srews are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.