background image

 

8

 

 

REPLACING THE LIGHT 

 

 

 

You cannot replaced the light bulbs, the entire light module has to be replaced. 

 

When changing the light modules, the contacts are live. 

 

Before changing the light module(s), unplug the appliance from the mains or switch off the circuit breaker in the 
fuse box. 

 

Remove the grease filter . 

 

Disconnect the terminal of LED light. 

 

Press LED light on the back of the front plate, take the LED light out. 

 

Replace the lamp(commercially available LED lamp (max.1.5w). 

 
 

 

 

Reinstall LED light module 

 

 

Press LED light on the front of front plate, install the LED light on the front plate. 

 

Connect the terminal of LED light and light leads. 

 

Reinstall the grease filter.

 

 

 

Max Power Voltage

 Picture

Lamp Cap ILCOS D code

1.5W

DC 12 V

——

DSS-1.5-S-33.2

/120

Lamp type

Square / Di

mesion: 

 33.2mm x 120mm

Summary of Contents for ERC60X

Page 1: ...ERC60X ERC90X INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS FOR EUROLUX RANGEHOOD Model ERC60X ERC90X AUSTRALIAN NEW ZEALAND PRODUCT WARRANTY ...

Page 2: ...pliance is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards CONTENTS IMPORTANT SAFETY INSTRUCTIONS 1 APPLIANCE DETAILS 2 INSTALLATION INSTRUCTIONS 3 INSTALLATION INSTRUCTIONS 5 OPERATING INSTRUCTIONS 6 MAINTENANCE AND CLEANING 7 TROUBLESHOOTING 9 AUSTRALIAN NEW ZEALAND PRODUCT WARRANTY 10 It is important that you retain these instructions proof of...

Page 3: ...and must be in a dry location Disconnect the power supply when any maintenance is carried out including changing light bulbs or inspecting filters Do not touch lights after appliance use This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction ...

Page 4: ... filter 2 1 1 Lower decorative chimney 2 2 1 Upper decorative chimney optional 3 1 Flange Optional 4 1 Exhaust pipe 5 2 The activated charcoal filter optional 10 7 Screws 5 x 50 11 7 Wall plugs 12 6 Screws 4 2 x 9 5 20 1 Hood fixing bracket 21 1 Chimney fixing bracket optional 2 2 4 3 2 1 5 1 20 12 11 21 10 ...

Page 5: ...5 171 472 600 900 Min 650mm Min 650mm 171 30 472 238 A B 258 226 229 600 900 170 172 472 unit mm Option A B 1 2 Chimney 3 Height 4 400 0 628 400 300 628 670 910 400 390 628 670 1000 500 490 728 770 1200 628 628 910 628 1000 728 1200 ...

Page 6: ... are levelled Mark a point 2 on the horizontal line B 40 mm to the vertical reference line Repeat this operation on the other side checking that the two marks are leveled Mark a point 3 on the horizontal line C 170 mm to the vertical reference line Repeat this operation on the other side checking that the two marks are leveled Fix the brackets Drill holes at the marked points with a ɸ10 mm drill b...

Page 7: ...20 mm the choice of which is left to the installer To install a ɸ 120 mm air exhaust connection insert the reducer flange 3 on the hood body outlet Fix the pipe 4 in position using sufficient pipe clamps not supplied Remove possible charcoal filters CHIMNEY ASSEMBLY Lower Decorative Chimney Fix the Lower Decorative Chimney to the hood body with 2 screws 12 4 2 x 9 5 supplied with the hood B ...

Page 8: ...ent ON OFF LIGHTING SWITCH Press on this switch to turn on the lights and press again to turn them off OFF MOTOR SWITCH Press on this switch to stop the motor operation SPEED SWITCH Press on this switch the motor runs at LOW speed SPEED SWITCH Press on this switch the motor runs at MEDIUM speed SPEED SWITCH Press on this switch the motor runs at HIGH speed ...

Page 9: ...o the hood make sure that they are completely dry The color of the filter surface may change throughout the time but this has no influence to the filter efficiency When fitting the filters into the hood pay attention that they are mounted in correct position the handle facing outwards ACTIVATED CHARCOAL FILTER RECIRCULATION VERSION REPLACING THE ACTIVATED CHARCOAL FILTER These filters are not wash...

Page 10: ...grease filter Disconnect the terminal of LED light Press LED light on the back of the front plate take the LED light out Replace the lamp commercially available LED lamp max 1 5w Reinstall LED light module Press LED light on the front of front plate install the LED light on the front plate Connect the terminal of LED light and light leads Reinstall the grease filter Max Power Voltage Picture Lamp ...

Page 11: ...lation entrance are not tightly sealed Take down the outlet and seal with glue Vibration The blade if damaged can cause vibrating Replace the blade The motor is not tightly fastened Fasten the motor tightly The cooker hood is not tightly fixed Fixed the cooker hood tightly Insufficient suction The distance between the cooker hood and the cooker top is too large Readjust the distance Too much venti...

Page 12: ... accessible without the need of special equipment and subject to the terms and conditions of this warranty repair or replace any parts which it considers defective WHAT IS NOT COVERED BY OUR WARRANTY 1 Incomplete or improper installation 2 Normal wear and tear e g cleaning light globes filters etc 3 Failure resulting from power surges and electrical storms 4 Insect or vermin infestation 5 Unauthor...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...ision of Shriro Australia Pty Limited 2 34 Davidson Street Greenacre NSW 2190 AUSTRALIA 1300 355 541 www shriro com au NEW ZEALAND 09 415 6000 www monacocorp co nz IM Ref ERC60X and ERC90X 3 2021 31FC FOR INDOOR USE ONLY ...

Reviews: