33
33
If you don’t select a time setting, then the stove will automatically select
setting 01 after flashing approx. 14 times and the heater will completely
process all the settings once until Sunday evening 24:00.
Attention!
All timer settings (maximum 10 per week) will be processed
completely one by one. Therefore, make sure that they do not contradict
each other!
If you wish, you can also readjust the thermostat, output and dimmer while
the timer is working.
You stop the operation of the timer by pressing on the TIMER ON/OFF
button. The stove will act as if there are no current timer settings and will
simply operate according to the thermostat and output settings. By pressing
the TIMER ON/OFF button again, you reactivate the timer setting.
To erase the timer setting, press on the TIMER SET button. 01 will start
flashing on the display. Using the + and - buttons, look for the setting number
that you want to erase and subsequently press on the C button (erasing the
timer setting). The timer setting will disappear immediately.
ATTENTION! If you want the stove to operate according to a timer programme,
it will not only have to remain on stand-by, but also switched on (using the
ON/OFF button). If this is not necessary, always switch off the stove using the
ON/OFF button, switch off the main switch and remove the plug from the
socket.
ATTENTION! Day and time are deleted if the electricity is cut off. This happens
not only when the plug is pulled out of the socket, but also if the main switch is
set to O (OFF). The timer settings however are stored. When the electricity is
restored and the timer settings are entered, then you need to reset the day and
hour settings immediately; otherwise the time will begin at 0.00!
If you do not enter any orders for approx. 15 seconds, the display will turn off.
Pressing any random button will reactivate the display.
Switching off
If you are not using the stove, you must switch it off using the main switch (you press
O) and remove the plug from the socket. Doing this will erases all the settings, also
day and time. Only the timer settings are stored.
Safety feature
The Siena atmospheric fireplace is equipped with an
overheating safeguard.
In
case of internal overheating, the overheating safeguard will switch the heater off.
This may occur if the heater cannot give off enough heat or if it cannot draw in
enough fresh air. As mentioned above, this is generally caused by (partially) covering
the heater, obstructing the air intake and/or outlet grills or installing the heater too
close to a wall or something similar.
If this happens, turn the fireplace off by switching the main switch to O and remove
the plug from the socket. Leave the fireplace to cool down for at least 15 minutes and
remove the cause of overheating. You can then switch the fireplace back on.