Do not fit the burner crowns, burner caps and trivets until after the cooker has been installed.
Locating the cooker
This appliance must be installed by an authorised person in accordance with this instruction manual, AS/NZS
5601 – Gas installations (installation and pipe sizing), local gas fitting regulations, local electrical regulations,
local water regulations, local health regulations, Building Code of Australia and any other government
authority.
Overhead clearances—(Measurement A)
Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s relevant
instructions. However, in no case shall the clearance between the highest part of the hob of the gas
cooking appliance and a range hood be less than 600 mm or, for an overhead exhaust fan, 750 mm
Side clearances—(Measurements B, & C)
Where B, measured from the periphery of the nearest burner
to any vertical combustible surface, or vertical
combustible surface covered with toughened glass or sheet
metal, is less than 200 mm, the surface shall be
protected to a height C of not less than 150 mm above the
hob for the full dimension (width or depth)
of the cooking surface area. Where the gas cooking
appliance is fitted with a ‘splashback’, protection of
the rear wall is not required.
Additional requirements for freestanding and elevated gas
cooking appliances— (Measurements D & E).
Where D, the distance from the periphery of the nearest
burner to a horizontal combustible surface is less than 200 mm, then E shall be 10 mm or more, or the
horizontal surface shall be above the trivet.
CHECKING GAS PRESSURES
Before installation check that the cooker is suitable for the gas supply. To do this check the gas type on the
carton sticker or on the data plate behind the bottom of the oven door. If the cooker is required to be used
with LPG, the supplied conversion kit must be used.
The following shows the supply and operating pressures for various gas supplies.
Operate pressure at appliance test point:
1.00 KPa (Natural gas); N2.75 KPa (Universal LPG gas)
The following table shows the injector sizes for each burner.