TESTING THE OPERATION
OF THE GAS COOKER
Gas leakage and operation of the appliance must be tested by the installer before leaving. Check all
burner flames are blue in colour, stable and completely ignite at both high and low flame settings with no
appreciable yellow tipping, carbon deposition, lifting, floating, lighting back or objectionable odour. Test
burners individually and in combination.
When maximum flame appearance is correct, then check the turn-down setting on each burner. If the
settings appear to be incorrect, proceed as follows:
•
Adjust the bypass screw mounted on the body of each hotplate control cock. This is accessible when
the control knob and the control panel are removed.
•
Check the ignition on all burners both separately and in combination.
•
Check the operation of the electrical components, if applicable.
•
If you are satisfied that the cooker is operating correctly, then turn it off and show the customer how to
use it. Make sure you ask the customer to operate the clock and controls.
Where the data plate is obscured by cabinetry when the cooker is in the installed position, place the
supplied duplicate data plate to a suitable adjacent surface or within the instruction manual for future
reference.
Gas Type: Natural Gas @ 1.00kPa Test Point Pressure
ULPG @ 2.75kPa Test Point Pressure