REV.0.02_COD.500201_A4
PAG. 20
3.5 Fuse
The fuses are used to protect the electrical circuits of machine from possible failure as overload or short circuits.
If fuse takes action the downstream connections and their function are no longer available.
The fuses must respect the characteristics (size, dimensions and tripping characteristic) indicated in the wiring
diagram.
3.5.1 Replacement of fuse
ATTENTION
The replacement of fuse must be done from authorized operators only.
Before making the replacement procedure of fuse, establish and remove the cause of the fault.
If necessary, contact our technical assistance service.
Replacement procedure of fuse:
•
Log off the machine in safety condition by dedicated safety device.
•
Access at the electrical panel.
•
Identify the fuse subjects to replacement, based on the wiring diagram.
•
Remove the related fuse from electrical panel.
•
Replace failure fuse with another fuse with same characteristics. The correct value of fuses are in the wiring
diagram.
If at the reactivation of electrical devices the new fuse intervene repeat the diagnosis and replacement procedure as
described previously.
ATTENTION
Use only fuses with the amperage and characteristics indicated in the wiring diagram.
The use of fuses other than those specified in the wiring diagram, void the warranty and can
cause the risk of damage the machine.