REV.0.02_COD.500201_A4
PAG. 52
13. CLOCK
•
The card has a real-time clock.
•
Time readings are also used when recording historical data.
14. HISTORICAL DATA
During the working cycle, the machine memorizes on a card all the working data of the wash cycles that have
been performed.
•
The card is able to record the fields described below for up to a max. of 200 cycles in the permanent memory.
The fields given in the example below are recorded for each cycle:
DATE
START TIME
PROGRAMME
MAX °C
HOLD>85°C
FAULTS
12/12/2012
12.00
Short
93°C
60 seconds
01
12/12/2012
13.05
Standard
94°C
180 seconds
01
•
When 95% of the memory is full the dump memory message appears on the display.
To clear the message, insert the USB key on the dedicated port and enter the menu. Select the USB menu and
download from the machine the historical data.
•
The various causes for machine shutdowns are indicated in the FAULTS section, identified by alarm code.