7. Function parameter
7.1 Menu grouping
Note:
“
★
”: In running status, can not modify the parameter setting
“•”: The actual testing data, can not be modified
“
☆
”: In stop and run statuses, both can be changed;
“
▲
”: “Factory parameter”, no change about it.
“_” means the factory parameter is related to power or model. Please check the details in the involved parameter
introduction.
Note: “Italic ³” means software version is C3.00 and the keyboard just like the above with MCU can do the functions.
Change limit refers to whether the parameters are adjustable.
y0.01 is used for parameters protection password. Parameter menu can be enter into only after inputting the right
password in the function parameter mode or user change parameter mode. When the y0.01 set to 0, the password is
canceled.
Parameter menu is not protected by password under user customized parameters mode.
F group is the basic function parameters,E group is to enhance function parameters, b group is a function of motor
parameters,d group is the monitoring function parameters.
Code
Parameter name
Functional Description
d0
Monitoring function group
Monitoring frequency, current, etc
F0
Basic function group
Frequency setting, control mode, acceleration and deceleration time
F1
Input terminals group
Analog and digital input functions
F2
Output terminals group
Analog and digital output functions
F3
Start and stop control group
Start and stop control parameters
F4
V/F control parameters
V/F control parameters
F5
Vector control parameters
Vector control parameters
F6
Keyboard and display
To set key and display function parameters
F7
Auxiliary function group
To set Jog, jump frequency and other auxiliary function parameters
F8
Fault and protection
To set fault and protection parameters
F9
Communication parameter group
To set MODBUS communication function
FA
Torque control parameters
To set parameters under torque control mode
Fb
Control optimization parameters
To set parameters of optimizing the control performance
FC
Extend parameters group
specialapplicationparameterssetting
E0
Wobbulate, fixed-length and counting
To set Wobbulate, fixed-length and counting function parameters
E1
Multi-stage command, simple PLC
Multi-speed setting, PLC operation
E2
PID function group
To set Built-in PID parameters
E3
Virtual DI, Virtual DO
Virtual I/O parameter setting
b0
Motor parameters
To set motor parameter
y0
Function code management
To set password, parameter initialization and parameter group display
y1
Fault query
Fault message query