7.1.1 d0 Group - Monitoring function group
Code
Parameter name
Setting range
Factory
setting
d0.00
Running frequency
Frequency converter theory
0.01Hz
d0.01
Set frequency
Actual set frequency
0.01Hz
d0.02
DC bus voltage
Detected value for DC bus voltage
0.1V
d0.03
output voltage
Actual output voltage
1V
d0.04
output current
Effective value for Actual motor current
0.01A
d0.05
output power
Calculated value for motor output power
0.1kW
d0.06
output torque
Motor output torque percentage
0.1%
d0.07
DI input status
DI input status
-
d0.08
DO output status
DO output status
-
d0.09
AI1 voltage (V)
AI1 input voltage value
0.01V
d0.10
AI2 voltage (V)
AI2 input voltage value
0.01V
d0.11
AI3 voltage (V)
AI3 input voltage value
0.01V
d0.12
Count value
Actual pulse count value in counting function
-
d0.13
Length value
Actual length in fixed length function
-
d0.14
Actual operating speed
Motor actual running speed
-
d0.15
PID setting
Reference value percentage when PID runs
%
d0.16
PID feedback
Feedback value percentage when PID runs
%
d0.17
PLC stage
Stage display when PLC runs
-
d0.18
High-speed pulse input frequency
High-speed pulse input frequency display, unit: 0.01Khz
0.01kHz
d0.19
Feedback speed (Unit: 0.1Hz)
Actual output frequency of converter
0.01Hz
d0.20
Remaining run time
Remaining run time display, it is for timing run control
0.1Min
d0.21
Linear speed
Show the line speed of DI5 high speed pulse sampling,
according to the actual sample pulse number per minute and
E0.07, calculate the line speed value.
1m/Min
d0.22
Current power-on time
Total time of current inverter power-on
Min
d0.23
Current run time
Total time of current inverter run
0.1Min
d0.24
HDI(DI5) impulse frequency
HDI(DI5) High-speed impulse input frequency display, unit: 1Hz
1Hz
d0.25
Communication set value
Frequency, torque or other command values set by
communication port
0.01%
d0.26
Encoder feedback speed
PG feedback speed, to an accuracy of 0.01Hz
0.01Hz
d0.27
Master frequency display
Frequency set by F0.03 master frequency setting source
0.01Hz
d0.28
Auxiliary frequency display
Frequency set by F0.04 auxiliary frequency setting source
0.01Hz
d0.29
Command torque (%)
Observe the set command torque under the torque control mode
0.1%
d0.32
Resolver position
Rotor position when rotary transformer is used as a speed
feedback
-
d0.33
ABZ position
Position information calculated from when ABZ incremental
feedback encoder is adopted
0
d0.34
Z signal counter
Encoder Z-phase signal count
-
d0.35
Inverter status
Display run, standby and other statuses
-
d0.36
Inverter type
1.G type (Constant torque load type)
2.F type (Fans/pumps load type)
-
d0.37
AI1 voltage before correction
Input voltage value before AI1 linear correction
0.01V
d0.38
AI2 voltage before correction
Input voltage value before AI2 linear correction
0.01V
d0.39
AI3 voltage before correction
Input voltage value before AI3 linear correction
0.01V
d0.40
Reserve
d0.41
Motor temperature inspection
function3
PT100 inspect motor temperature value
0 °C