44
45
NEURN030000_220_A
NEURN030000_220_A
7.1.14 FC Group - Extended parameter group
Code
Parameter name
Setting range
Factory
setting
Change
FC.00
Undefined
FC.01
Proportional linkage coefficient
0.00~10.00
0
☆
FC.02
PIDstart deviation
0.0~100.0
0
☆
7.1.15 E0 Group - Wobbulate, fixed-length and counting
Code
Parameter name
Setting range
Factory
setting
Change
E0.00
Swing setting manner
0: Relative to center frequency
1: Relative to maximum frequency
0
☆
E0.01
Wobbulate range
0.0%~100.0%
0.0%
☆
E0.02
Sudden jump frequency range
0.0%~50.0%
0.0%
☆
E0.03
Wobbulate cycle
0.1s~3000.0s
10.0s
☆
E0.04
Triangle wave rise time coefficient
0.1%~100.0%
50.0%
☆
E0.05
Set length
0m~65535m
1000m
☆
E0.06
Actual length
0m~65535m
0m
☆
E0.07
Pulse per meter
0.1~6553.5
100.0
☆
E0.08
Set count value
1~65535
1000
☆
E0.09
Specified count value
1~65535
1000
☆
E0.10
Reduction frequency pulse number
0:Invalid; 1~65535
0
☆
E0.11
Reduction frequency
0.00Hz~F0.19(Max frequency)
5.00Hz
☆
7.1.16 E1 Group, Multi-speed, Simple PLC
Code
Parameter name
Setting range
Factory
setting
Change
E1.00
0-stage speed setting 0X
-100.0%~100.0%
0.0%
☆
E1.01
1-stage speed setting 1X
-100.0%~100.0%
0.0%
☆
E1.02
2-stage speed setting 2X
-100.0%~100.0%
0.0%
☆
E1.03
3-stage speed setting 3X
-100.0%~100.0%
0.0%
☆
E1.04
4-stage speed setting 4X
-100.0%~100.0%
0.0%
☆
E1.05
5-stage speed setting 5X
-100.0%~100.0%
0.0%
☆
E1.06
6-stage speed setting 6X
-100.0%~100.0%
0.0%
☆
E1.07
7-stage speed setting 7X
-100.0%~100.0%
0.0%
☆
E1.08
8-stage speed setting 8X
-100.0%~100.0%
0.0%
☆
E1.09
9-stage speed setting 9X
-100.0%~100.0%
0.0%
☆
E1.10
10-stage speed setting 10X
-100.0%~100.0%
0.0%
☆
E1.11
11-stage speed setting 11X
-100.0%~100.0%
0.0%
☆
E1.12
12-stage speed setting 12X
-100.0%~100.0%
0.0%
☆
E1.13
13-stage speed setting 13X
-100.0%~100.0%
0.0%
☆
E1.14
14-stage speed setting 14X
-100.0%~100.0%
0.0%
☆
E1.15
15-stage speed setting 15X
-100.0%~100.0%
0.0%
☆
E1.16
Simple PLC running mode
0: Stop after single running
1: Hold final value after single running
2: Circulating
0
☆
E1.17
Simple PLC power-down memory selection
Units digit:
Power-down memory selection
0: Power-down without memory
1: Power-down with memory
Tens digit: Stop memory selection
0: Stop without memory
1: Stop with memory
11
☆
E1.18
0 stage running time T0
0.0s(h)~6500.0s(h)
0.0s(h)
☆
E1.19
0 stage ac/deceleration time selection
0~3
0
☆
E1.20
1 stage running time T1
0.0s(h)~6500.0s(h)
0.0s(h)
☆