Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
sales@euronorm.nl •
I
euronormdrives.com
48
49
NEURN030000_220_A
NEURN030000_220_A
7.1.20
y0 Group - Function code management
Code
Parameter name
Setting range
Factory
setting
Change
y0.00
Parameter initialization
0: No operation
1: Restore default parameter values, not including
motor parameters
2: Clear history
3: Restore default parameter values, including
motor parameters
4: Backup current user parameters
501: Restore from backup user parameters
10: Clear keyboard storage area3
11: Upload parameter to keyboard storage area 1
12: Upload parameter to keyboard storage area 2
21: Download the parameters from keyboard
storage 1 area to the storage system 3
22: Download the parameters from keyboard
storage 2 area to the storage system 3
0
★
y0.01
User password
0~65535
0
☆
y0.02
Function parameter group display selection
Units digit: D group display selection
0: Not displays 1: Displays
Tens digit: E group display selection
(The same above)
Hundreds digit: b group display selection
(The same above)
Thousands digit: y1 group display selection
(The same above)
Tens thousands digit: L group display selection
(The same above)
11111
★
y0.03
Personality parameter group display selection
Units digit:User’s customization parameter display
selection
0: Not display 1: Display
Tens digit: User’s change parameter display
selection
0: Not display 1: Display
00
☆
y0.04
Function code modification properties
0: Modifiable
1: Not modifiable
0
☆