Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
sales@euronorm.nl •
I
euronormdrives.com
Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
sales@euronorm.nl •
I
euronormdrives.com
80
81
NEURN030000_220_A
NEURN030000_220_A
Parameter lock password verification: (If the return code is 8888H, it indicates that password verification is passed)
Password address
Enter password
C000
*****
Digital output terminal control: (write only)
Command address
Command content
2001
BIT0: SPA output control
BIT1: RELAY2 output control
BIT2 RELAY1 output control
BIT3: Manufacturer reserves the undefined
BIT4: SPB switching quantity output control
Analog output DA1 control: (write only)
Command address
Command content
2002
0 to 7FFF indicates 0% to 100%
Analog output DA2 control: (write only)
Command address
Command content
2003
0 to 7FFF indicates 0% to 100%
SPB high-speed pulse output control: (write only)
Command address
Command content
2004
0 to 7FFF indicates 0% to 100%
Inverter fault description:
Inverter fault address:
Inverter fault information:
8000
0000: No fault
0001: Inverter unit protection
0002: Acceleration overcurrent
0003: Deceleration overcurrent
0004: Constant speed overcurrent
0005: Acceleration overvoltage
0006: Deceleration overvoltage
0007: Constant speed overvoltage
0008: Control power failure
0009: Undervoltage fault
000A: Inverter overload
000B: Motor Overload
000C: Input phase loss
000D: Output phase loss
000E: Module overheating
000F: External fault
0010: Communication abnormal
0011: Contactor abnormal
0012: Current detection fault
0013: Motor parameter auto tunning fault
0014: Encoder/PG card abnormal
Inverter fault address:
Inverter fault information:
8000
0015: Parameter read and write abnormal
0016: Inverter hardware fault
0017: Motor short to ground fault
0018: Reserved
0019: Reserved
001A:Running time arrival
001B: Custom fault 1
001C: Custom fault 2
001D: Power-on time arrival
001E: Load drop
001F: PID feedback loss when running
0028: Fast current limiting timeout
0029: Switch motor when running fault
002A: Too large speed deviation
002B: Motor overspeed
002D: Motor overtemperature
005A: Encoder lines setting error
005B: Missed encoder
005C: Initial position error
005E: Speed feedback error