Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
sales@euronorm.nl •
I
euronormdrives.com
Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
sales@euronorm.nl •
I
euronormdrives.com
90
91
NEURN030000_220_A
NEURN030000_220_A
V-5 Multi-speed running
V-5-1 Electrical diagram
S1
S2
S3
S4
380V 50/60Hz
Three phase input power supply
Circuit breaker
%
Motor
M
FWD/STOP
First segment speed
Second segment speed
Third segment speed
Multi segment speed operation
V-5-2 Connection:
The control terminals DI1 and COM are short-circuited and run forward command (0 segment speed setting 0X).
DI2, DI3 and DI4 correspond to 3-segment speed short to COM and 100% parameter value corresponds to 50HZ.
(Take the three-stage speed as an example, up to 16-stage speed control can be realized).
V-5-3 Parameter setting:
No.
Code
Parameter name
Setting
range
F0.03
Frequency source master setting
Multi-speed operation setting
6
F0.11
Command source selection
Terminal block control (LED on)
1
F0.13
Acceleration time 1
0.0s~6500s
2.0s
F0.14
Deceleration time 1
0.0s~6500s
2.0s
F1.00
DI1 terminal function selection
Forward run (FWD)
1
F1.01
DI2 terminal function selection
Multi-speed terminal 1
12
F1.02
DI3 terminal function selection
Multi-speed terminal 2
13
F1.03
DI4 terminal function selection
Multi-speed terminal 3
14
E1.00
0-stage speed setting 0X
0-stage speed frequency setting percentage
20.0%
E1.01
1-stage speed setting 1X
1-stage speed frequency setting percentage
40.0%
E1.02
2-stage speed setting 2X
2-stage speed frequency setting percentage
60.0%
E1.04
4-stage speed setting 4X
3-stage speed frequency setting percentage
100.0%
Options:
E1.51
Multi-stage command 0 reference
manner
0 ~ 7 selection, according to the site require-
ments to set the corresponding way
0