2. WARNING 

2.1. SAFETY

Using the machine in an incorrect way or in non-compliance of the safety instructions indicated in 
this manual can cause death or serious injuries.

Read carefully all the working and safety instructions and the warnings contained in this manual 
before starting your machine.

•  Respect all the safety standards before running the equipment.
• 

Use the equipment only for the applications specified in the manual.

• 

Always remain alert when using the equipment.

•  Transport the machine using the handles or the appropriate grips.
•  During the breaks, disconnect electrically the machine.

•  Run the equipment to its nominal voltage.
• 

Let at least 50 cm of free space between the equipment and any obstacle so that the air   flow 

is not blocked. 

• 

Know how to quickly stop the equipment in case of necessity.

• 

Never use the equipment while it is running abnormally or it is defective.

• 

Do not direct a water jet or flammable liquid on the machine.

•  Never direct an air jet or product jet on a person or an animal.
• 

Do not touch warm surfaces of the equipment.

• 

Always wear adequate body protections (glasses, gloves, overall and mask) and pay attention 

to long hair.

•  Never touch moving parts.
•  Do not insert any object or the hands inside the protection grids to avoid any accident or 

damage to the machine.

•  For any outside job, only use appropriate extension cords.

•  Maintain the equipment carefully and clean it properly after every use.
•  Disconnect the equipment before any intervention.
• 

Avoid absolutely to unscrew any connection while the machine is under pressure.

•  Check the damaged parts.
• 

Do not clean the plastic parts with solvant.

•  In case of damage of the electric cable or the plug, do not run the machine and contact a 

licensed After-Sale Service to put genuine parts instead of the defective ones.

• 

In case of needed After-Sale Service, always specify the machine model and its serial number.

•  For any replacement of parts, only use genuine parts.

•  Do not cut or dismantle the protection grids.
• 

Do not transport the compressor while it is under pressure or in operation.

• 

Do  not  make  any  modifications  to  the  machine.  In  particular,  do  not  drill  holes,  weld  or 

deliberately deform the compressed air tank.

Summary of Contents for 90284

Page 1: ...SET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 EUROPRO 50TR 100TR R f 90469 90284 User manual Editi...

Page 2: ...roy 13790 ROUSSET T l 33 0 4 42 29 08 96 contact euromair com SUMMARY 1 USER MANUAL p 3 1 1 Importance of the manual p 3 1 2 Receivers of the manual p 3 2 WARNING p 4 2 1 Safety p 4 2 2 Electric conne...

Page 3: ...caused by the non compliance of the safety standards and rules This manual must be kept near the machine within reach of the user and held in good condition until the final destruction of the machine...

Page 4: ...et or product jet on a person or an animal Do not touch warm surfaces of the equipment Always wear adequate body protections glasses gloves overall and mask and pay attention to long hair Never touch...

Page 5: ...the machine as well as children and animals In case of installation of the machine on scaffolding or a plan above ground level attach the machine to avoid any fall while operating Do not install the...

Page 6: ...nwind it entirely otherwise the equipment can be damaged The section must be proportional to the length of the cord 2 3 END OF LIFE OF THE PRODUCT At its end of life the machine must not be eliminated...

Page 7: ...STICS EUROPRO 50TR EUROPRO 100TR Rotation speed 1215 RPM 1300 RPM Flow rate of air absorbed 820 L min 49 m3 h 1080 L min 65 m3 h Quantity of oil crankcase 1 4 L 1 6 L Oil consumption 1 5 g h 1 2 g h M...

Page 8: ...02007 477A ENG P8 3 YOUR MACHINE continued 3 3 IDENTIFICATION OF THE COMPONENTS EUROPRO 50TR A Compression head B Oil dipstick C Drain plug D Air filter E Autonomous valve F Express coupling G Air val...

Page 9: ...EUROPRO 100TR P9 3 YOUR MACHINE continued 3 3 IDENTIFICATION OF THE COMPONENTS EUROPRO 100TR A Compression head B Oil dipstick C Drain plug D Air filter E Autonomous valve F Express coupling G Air va...

Page 10: ...8 bar Once this maximum load has been reached the autonomous valve will decompress 6 Connect the device spraying machine stapler etc to the compressor on the express coupling F then open the valve G...

Page 11: ...Air leakage Broken valve plate Replace the filters Screw back in or replace purge Check for leaks Replace the regulating filter Contact the After Sales Service Engine rumbles but won t start Capacitor...

Page 12: ...w it out with a blower to clean it 6 2 EVERY 200 WORKING HOURS Replacing air filter Unscrew or unclip the air filter D and replace it Changing oil Contact our After Sales Service 04 42 29 08 96 Discon...

Page 13: ...Three phased compressor Model EUROPRO 50TR EUROPRO 100TR COMPLIES WITH THE DIRECTIVES Machines 2006 42 CE Low voltage 2014 35 UE CEM 2014 30 UE ROHS 2011 65 UE Noise emissions 2005 88 CE ROUSSET JANU...

Page 14: ...s filters oils chains and quick release clip The warranty also excludes the equipment on which the serial number was erased or made illegible on which unauthorized people made attempts of repair which...

Page 15: ...ent A file number shall be given to the customer and an answer shall be provided within 48 working hours after reception provided that the request for warranty is considered as full In the event the e...

Page 16: ...ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 User manual EUROPRO 50TR EUROPRO 100TR 202007 4...

Reviews: