Page 12
DV 42 Indoor Gas Fireplace
Installation
Figure 16b.
Corner installation.
Figure 16c.
Flex installation. (NG Models Only)
45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut
the PXT-20 to suit, and attach it to the PEL-45. Slide the fireplace
into position and attach to the termination.
45° or less Corner Installation.
Use an PTO-4 termination and an PFL-1 or PFL-2/PFL-2 (12"
or 24" compressed length) and a frame, if appropriate. Flex
may be turned to obtain desired degree of angle required
but must not exceed 45°.
Note: A wall venting kits is available for both the straight
and the corner installation. The kit includes a heat shield, a
PXT-12, and a termination with a mounting frame.
PEL-45 Elbow
PEL-90 Elbow
PXT-18
Important
:
A corner installation is available for DV 42 Top
Vent units
ONLY
.