Page 14
DV 42 Indoor Gas Fireplace
Installation
•
Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports.
•
Place the springs, supplied with the pipe kit, between
the outer and inner pipes to keep the pipes separate
and avoid any possible hot spots.
•
European Home recommends the use of a flex section
for the final pipe connected directly to the fireplace
offering greater flexibility of installation and absorption
of movement.
•
When penetrating a combustible ceiling, a ceiling
firestop must be used.
•
European Home recommends that all exterior corners
and joints be sealed with exterior caulking however
we encourage you to consult your Building Envelope
Engineer or Waterproofing Consultant for further
recommendations.
Connection and installation of the vent components must
adhere to the following:
Section 3-3-2: VENTING COMPONENTS
The following components and associated European Home
part numbers are available for installation of a wall mounted
termination. Use only European Home vent components. Use
of non-European Home parts will void the warranty and may
impede operation of the fireplace.
•
Use any combination of rigid and flex pipe as required.
•
Flex sections may be stretched up to 50% of their total
length (e.g. a 24” section maybe stretched to 36”).
•
Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue..
•
Ensure the pipe ends male to female slide in a minimum
of 11/2” of overlap.
•
Ensure all runs are supported with a minimum of 3
supports per 10’ of venting.
•
When hanging/supporting venting, ensure that 1”
clearance is maintained on sides and bottom of vent runs
and 2” above horizontal vent runs to any combustible
material.
a - Termination
PTO-4 (3" Length)
PTO-4F (3" Length)
B - Frame Kits
MSr (Stucco Frame)
MOSr (Stucco Frame)
BSr-4 (4" Brick Frame)
BSr-6 (6" Brick Frame)
C - Flex Sections
PFL - 1 (12" f/f Section)
PFL - 18 (18" f/f Section)
PFL - 2 (24" f/f Section)
PFL - 3 (36" f/f Section)
PFL - 4 (48" f/f Section)
PFL - 6 (72" f/f Section)
D - rigid Sections
PXT - 5 (5" f/f Section)
PXT - 10 (10" f/f Section)
PEXT - 1 (12" f/f Section)
PXT - 20 (20" f/f Section)
PEXT - 2 (24" m/f Section)
PEXT - 3 (36" m/f Section)
PEXT - 4 (48" m/f Section)
PEXT - 6 (72" m/f Section)
E - Elbows
PEL-90MM (m/m 90
º
Elbow)
PEL-90FF ( f/f 90
º
Elbow)
PEL-90FM ( f/m 90
º
Elbow)
PEL-45FM ( f/m 45
º
Elbow)