DV 42 Indoor Gas Fireplace
Operation
Section 9: Start-up Sequence
•
If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service technician.
Force or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas:
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone
in your building.
•
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
To Turn Off Gas To Appliance:
3. Push in gas control knob slightly and turn
clockwise
to "Off". Do not force.
4. Replace the lower horizontal access panel.
1. Turn off remote switch.
2. Lift out the lower horizontal access panel
.
with Continuous Pilot
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
WARNING!
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
Lighting Instructions:
1. STOP! Read the safety information above on this label.
2. Lift out the lower horizontal access panel
.
3. Push in gas control knob and turn clockwise
to "OFF."
4. Wait five (5) minutes to clear out any gas. Smell for gas,
including near the floor. If you then smell gas, STOP! Follow
"B" in the safety information above on this label. If you don't
smell gas, go to the next step.
5. Locate pilot burner
(See illustration at right.)
and follow
steps below.
6. Turn knob on gas control counter clockwise
to "PILOT."
7. Push in gas control knob completely and hold. Light with
Piezo Igniter button. Continue to hold the control knob in
for about (1) minute after the pilot is lit. Release the knob
and it will pop back up. Pilot should remain lit. If it goes
out repeat steps 3 through 8.
•
If knob does not pop up when released, stop and
immediately call your service technician or gas supplier.
•
If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician or
gas supplier.
8. Push in gas control knob and turn counter-clockwise
to "ON."
9. Replace the lower horizontal access
panel.
10. Turn on remote switch to ignite fire.
nOTE:
Gas control knob cannot be turned from "PILOT" to "OFF" unless knob is
pushed in slightly. Do not force.
Model
DV 42