Page 24
DV 42 Indoor Gas Fireplace
Maintenance
1. Locate the lead to the battery backup, (remove)
(Refer to schematic, below)
2. Locate the AC/DC wall transformer, (Unplug connector)
(Refer to schematic, below)
Troubleshooting: (SIT - IPI Electronic)
1.
2.
If your fireplace still does not operate correctly, consult your
dealer or the manufacturer.
Troubleshooting:
(SIT Nova 820).
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTION
Noisy Pilot Flame
Locate pilot adjustment screw
on gas control valve. Flame is
decreased by turning adjustment
screw clockwise.
Pilot won’t ignite
Disconnect remote wires and try
to light pilot. If pilot now works,
remote connections are faulty.
Check wiring diagram Figure 33.
Main burner will not
ignite
1. Check wiring (see Figure 33).
2. Check wall switch for proper
connection.
Models
DV 42 E
Models
DV 42
Replacement Parts List
DV 42
DV 42 E
NG Gas Valve
RGC1006
RGC1004
LP Gas Valve
RGC1005
RGC1003
NG Pilot
RPA020
RPA003
LP Pilot
RPA021
RPA004
NG Burner
RBH3801
~
LP Burner
RBH3802
~
NG Oriface
R0R1120
R0R1151
LP Oriface
R0R1121
R0R1152
Door
RDTH38
RDTH38
Base
RLG549
~