DV52 Gas Fireplace
rev.101207
Installation
Figure 15.
Straight, vertical venting
showing required PXT-10 adaptor (supplied
with the PVTK-1 termination).
*
All venting: minimum 1" clearance to all vertical combustibles,
minimum 2" to all horizontal combustibles.
Figure 17.
Vertical venting with 2 offsets (1 offset= two
90° bends).
Figure 16.
Vertical venting with 1 offset (1 offset= two
90° bends).
PEXT
PEXT
PXT-10
Figure 16a.
RHS8 Installation. Install by sliding over vent pipe where it passes through
the combustible construction.
Figure 16b.
RHS101 Installation. Install by sliding over vent pipe where it passes
through the combustible construction.
Framing
Drywall
RHS101 Heat Shield,
Inner Section.
Vent from fireplace
RHS101 Heat Shield,
Outer Section.
Termination
32’
RHS8
Heat Shield
1" min.
Both sides
typical
2" min.
1" min.