Page 8
DV52 Gas Fireplace
rev.101207
B
A
C
Power Vent models, LDVPV47
EDVRSPV58, and EDVWSPV58
to be used within the shaded area
of graph. See index of this guide
for applicable product page.
Installation
Figure 9a.
DV 52 Top Vent Venting Graph
NOTES:
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs
must
fall within the limits set by the venting graph
(see Figure 9a).
Example 1:
For our shortest venting configuration use components A and E
(see Figure 9a)
.
Figure 10.
Typical top vent installation. If the 90° elbow is installed directly on the
fireplace, for height to the center of the termination see chart on Page 3.
Important:
An inspection of the explosion relief flappers and door must be made prior to
lighting the fireplace. This will ensure the door gasketing material will provide
an adequate seal during operation.
PEL
RHS101
Horizontal Venting
Figure 11.
Typical top vent installation. The solid sections can be used in various
combinations to obtain the desired vent run. The vent run
must
fall
within the limits set by the venting graph.
90° Elbow
PEXT Section
Termination
If the 'X' falls on or above the top boundary of the shaded area, the installation is
acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 84" and the horizontal run to the wall flange
of the vent termination is 36", the installation is acceptable.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 108" and the horizontal run to the wall flange
of the vent termination is 120", the installation is acceptable.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 48" and the horizontal run to
the wall flange of the vent termination is 108",
the installation is NOT ALLOWED.
Available Top Vent Components
The following components are available for through-the-wall venting:
5" / 8" Venting
A - Termination
PTO-4 (4" Length)
PTO-4F (4" Length)
B - Stucco Kits
MSR (Stucco Frame)
MOSR (Stucco Can)
BSR ( Brick Can)
C - Flex Sections
PFL-1 (12" Section)
PFL-2 (24" Section)
PFL-3 (36" Section)
PFL-4 (48" Section)
D - Rigid Sections
PEXT-1 (12" m/f Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
E - Elbows
PEL-90MM (m/m 90° Elbow)
PEL-90FF (f/f 90° Elbow)
PEL-90FM (f/m 90° Elbow)