GAS INSTALLATION
J Series Outdoor Gas Fireplace
European
Home
.com
10
The
J Series Outdoor Gas Fireplace
is shipped from the factory for use with natural gas.
A kit to convert the fireplace to propane (LP) is available. The conversion must be performed by a qualified
service person. Contact your local gas supplier.
This product must be installed by a licensed plumber or gasfitter.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 /NFPA 54; National Fuel Gas Code; Natural Gas and Propane Installation Code, CSA B149.1;
or Propane Storage and Handling Code, CSA B149.2, as applicable.
The fireplace and its individual shutoff valve must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
Note
INSTALL THE GAS SUPPLY
For the
J Series Outdoor Gas Fireplace
a 45/8” x 7” opening in the lower left side is provided for the gas supply.
Alternately an identical opening is on the right.
The gas supply piping must have a separate gas shutoff valve and a capped, 1/8” pipe tapping upstream of the
valve for the purpose of reading pressure. A service shutoff valve must be placed within six feet of the fireplace
gas control valve.
Verify the gas pressure using the upstream 1/8” pipe tap.
The gas supply line must terminate with a 1/2” male flare fitting.