SPECIFICATIONS and DIMENSIONS

J Series Outdoor Gas Fireplace

                 

                                                                                                                                                       European

Home

.com

5

CERTIFICATION

OMNI-Test Laboratories, Inc. has certified that the 

J Series Outdoor Gas Fireplace

 complies with the ANSI 

Z21.97-2014/CSA 2.41-2014 

Outdoor Decorative Gas Appliances

 standard.

SPECIFICATIONS

Mode

l

J60, J60-ST

Gas

Natural Propane

Input

Btu/hr

76,000

76,000

Minimum

Supply Pressure

(NG)

in. w.c.

7” w.c.

kpa

1.74 kPa

Minimum

Supply Pressure

(LP)

in. w.c.

11” w.c.

kpa

2.74 kPa

Manifold Pressure

(NG)

in. w.c.

6.3” w.c.

kpa

1.57 kPa

Manifold Pressure

(LP)

in. w.c.

10.4” w.c.

kpa

2.59 kPa

Electrical Rating

V DC

1.5

Summary of Contents for J-60

Page 1: ...this or any other appliance WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicin...

Page 2: ...Home com TABLE OF CONTENTS Important Safety Information 3 Important Safety Information About Propane 4 Specifications 5 Clearances 7 Installation 8 Gas Installation 10 Operating the Fireplace 12 Maintenance 13 Parts List 14 Warranty Appendix A ...

Page 3: ...r other flammable materials should not be hung from the appliance or placed on or near the appliance Anyguardorotherprotectivedeviceremovedforservicingtheapplianceshallbereplacedpriortooperating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning ma...

Page 4: ...ission CAN CSA B339 as applicable 2 provided with a listed overfilling prevention device and 3 provided with a cylinder connection device compatible with the connection for the appliance If a propane hose is used to connect a propane cylinder to the fireplace the following is required Inspect the hose before each use of the fireplace The hose assembly must be replaced prior to the fireplace being ...

Page 5: ... the ANSI Z21 97 2014 CSA 2 41 2014 Outdoor Decorative Gas Appliances standard SPECIFICATIONS Model J60 J60 ST Gas Natural Propane Input Btu hr 76 000 76 000 Minimum Supply Pressure NG in w c 7 w c kpa 1 74 kPa Minimum Supply Pressure LP in w c 11 w c kpa 2 74 kPa Manifold Pressure NG in w c 6 3 w c kpa 1 57 kPa Manifold Pressure LP in w c 10 4 w c kpa 2 59 kPa Electrical Rating V DC 1 5 ...

Page 6: ...nd DIMENSIONS 6 J Series Outdoor Gas Fireplace EuropeanHome com Dimension J60 A 651 8 B 60 C 491 4 Dimension J60 ST A 651 8 B 60 C 491 4 71 2 71 2 171 2 27 18 27 18 171 2 Model J60 ST see through Model J60 single sided ...

Page 7: ...5 Fireplace opening to side wall in front of fireplace E 0 Side of fireplace to combustible side wall F 6 Top of fireplace opening to combustibles G 17 Top of fireplace opening to combustible mantel H 18 Front of fireplace to back combustible wall 12 Maximum depth of mantel CLEARANCES TO COMBUSTIBLES Clearances Front Elevation View MANTEL SIDEWALL TRIM TRIM A B C D E C F G Clearances Top Plan View...

Page 8: ...Even though these materials may have been flame proofed made fire resistant or are fire rated they are considered combustible Standard and Type X drywall are both combustible NON COMBUSTIBLE MATERIALS A material is non combustible when it cannot catch fire and burn The table below shows a list of materials which may be used to enclose this fireplace Only these materials may be used with this firep...

Page 9: ...se of your enclosure and must be allowed to drain away from the enclosure An appropriate length of 11 2 2 PVC pipe installed at the base of the enclosure which would run down and out is recommended These openings must be checked for blockage periodically While combustible framing is permitted metal framing is more appropriate for an outdoor enclosure A typical installation is shown The fireplace i...

Page 10: ...49 2 as applicable The fireplace and its individual shutoff valve must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Note INSTALL THE GAS SUPPLY For the J Series Outdoor Gas Fireplace a 45 8 x 7 opening in the lower left side is provided...

Page 11: ...h a hook for easy removal of the tank Ventilation openings must be provided at floor level of the enclosure and must have a total free area of not less than 1 2 square inch per lb 7 1 cm2 kg of stored fuel capacity If ventilation openings at floor level are in a sidewall there must be at least two openings The bottom of the openings must be 1 in 25 4 mm or less from the floor level and the upper e...

Page 12: ...s supplier call the fire department LIGHTING INSTRUCTIONS 1 Push in gas valve knob slightly and turn to OFF 2 Wait five 5 minutes before attempting to light the burner 3 Push the igniter button and hold You will hear a repeating clicking sound 4 Turn gas valve knob to PILOT position and push all the way in The pilot should light If so release the igniter button 5 If the flame does not light after ...

Page 13: ...brush Remove any debris from the area under the hearth panel 3 Clean the pilot shield with a vacuum cleaner Cleaning the Stainless Steel 1 With all parts of the fireplace at room temperature carefully remove the hearth panel 2 Using a high quality stainless steel cleaner be sure to softly clean WITH the grain The flames should look like the picture below The burner must be replaced prior to the ap...

Page 14: ...1 AAA battery 2 Gas Valve 3 Pilot Assembly 4 Main Burner Orifice 1 2 4 3 4 J SERIES OUTDOOR GAS FIREPLACE PARTS LIST Gas Valve Manual REPL JVF GS GV 01 Electronic Ignition REPL JVF GS IM 01 Pilot Assembly REPL JVF GS PA 01 For replacement parts and customer service please contact your local hearth products dealer ...

Page 15: ...________________ DATE INSTALLED ______________________________________ FUEL ______________________________________ MEASURED AFTER INSTALLATION INLET PRESSURE ______________________________________ MANIFOLD PRESSURE ______________________________________ DATE PURCHASED ______________________________________ DEALER ______________________________________ INSTALLER ____________________________________...

Page 16: ... part assumes the remaining warranty of the original product or ninety 90 days from the date of replacement or repair whichever provides longer coverage for you When a product or part is exchanged any replacement item becomes your property and the replaced item becomes the property of European Home All warranty claims must be submitted through the dealer from which you purchased the product Check ...

Page 17: ...APPENDIX A J Series Outdoor Gas Fireplace EuropeanHome com 17 NOTES ...

Page 18: ...18 J Series Outdoor Gas Fireplace EuropeanHome com IGJVF 150713 EUROPEAN HOME a division of Europa Ja Inc 376 Washington Street Suite 203 Malden MA 02148 www europeanhome com ...