Place the burner module in the center of the fireplace and connect the gas supply to the flexible
gas supply connector provided with the burner. The gas supply line must terminate with a male
½” NPT pipe thread in the rear of the fireplace. The gas supply piping should have a separate gas
shutoff valve and a 1/8” NPT plugged tapping up stream of the valve. The Gas Stones with Fusion
Basket and its main control valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa). The Gas Stones
with Fusion Basket must be isolated from the gas supply piping system by closing the main control
valve during any pressure testing of the gas supply system at test pressures equal to or less than ½
psi (3.5 kPa).
GAS SUPPLY
INSTALLING THE BURNER
Warning: This product
must be installed by a
licensed plumber or gas
fitter when installed within
the Commonwealth of
Massachusetts.
Figure 4
Figure 3b
Yellow-tipped
Wire (SW)
Red-tipped
Wire (TC)
RESET
button
Place 4 AA batteries in the battery case and con-
nect the battery case to the receiver as shown in
Figure 3a.
Ensure that the wiring is connected as shown in
Figure 3b.
Figure 3a
RESET
button