Place the Fusion Basket over the burner
so the burner is centered in the opening
in the Fusion Basket as in Figure 6.
After the gas supply has been connected, open the main supply and apply a soapy water solution
to all the fittings to check for gas leaks.
Never use a flame to test for leaks.
If you are installing a
propane burner, check that the air shutter (see Figure 5) is in the open position. Replace the burner
in the burner module. Ensure that the burner inlet tube is in the shutter box.
Air shutter shown in the
open position
(for propane only)
Figure 5
Figure 6
Summary of Contents for VBM-LP-02