18
1. STOP! Read the safety information above.
2. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot
by hand.
3. Push the
OFF
button on the remote control to insure the
appliance is off.
4. Wait five (5) minutes to clear out any gas. Then smell for
gas including near the floor. If you smell gas, STOP! Follow
“B” in the safety information above. If you don’t smell gas,
go to the next step.
5. Press the
OFF
and
LARGE FLAME
(
Ç
) buttons
simultaneously. Release the buttons once you hear a
beeping noise. This acoustic signal tells you that the start
sequence has begun. Further short signals will continue
until main gas flows and the burner is lit. If the pilot or
burner does not light, go back to Step 3, above.
6. Use the
LARGE FLAME
(
Ç
) and
SMALL FLAME
(
È
)
buttons to adjust the flame height.
LIGHTING THE FIRE
OFF
LARGE
FLAME
SMALL
FLAME
SET
RESETTING THE SYSTEM
This procedure resets the system as well as ‘pairs’ the remote and the receiver. It is only needed to be
performed once but can be done as often as necessary. To reset the system:
1. press and hold the receiver reset button until you hear the second of two beeps then
2. release the reset button and, within twenty seconds,
3. press the
SMALL FLAME
button on the remote until you hear two confirming beeps
The receiver and remote are now each reset and ready for normal operation.
TO TURN OFF THE HEATER
7. Push the
OFF
button on the remote control to turn the appliance off.
RESET
BUTTON
Summary of Contents for VBM-LP-02
Page 25: ...25 NOTES ...