MAINTENANCE

 A qualified service agency should conduct an annual inspection and maintenance of your Gas 

Stones with Fusion Basket, the fireplace, chimney, and the installation to keep it running safely.  

The following procedures should be performed only by a qualified service person. The gas supply 

should be turned off whenever a maintenance procedure is performed. All parts of the fireplace 

that are removed for servicing must be replaced prior to operation.

Cleaning the Stones and Burner. 

With all parts of the fireplace at room temperature, carefully remove and clean the stones with a 

soft bristled brush.  Never use a vacuum cleaner to clean the stones. Clean the burner surface with 

a brush.  Replace the components according to the instructions starting on page 11 of this manual.

Inspecting the Chimney

An inspection of the chimney should be made as part of the annual service appointment.  The 

chimney must have no blockage and be in good repair.  

Replacing the Batteries

With all parts of the fireplace at room temperature, remove the stones and embers. Remove the 

Fusion Basket from the fireplace. Find the battery compartment door on top of the receiver and 

slide it open. Remove the four batteries and, minding the correct polarity, replace them with fresh 

AA batteries. Close the battery compartment cover and re-set the Fusion Basket, embers and 

stones according to the previous instructions.

Battery 

Compartment

RESET button

RESET

Summary of Contents for VBM-LP-02

Page 1: ...ppliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed...

Page 2: ...Information 4 Specifications and Dimensions 6 Before You Begin 9 Fireplace Requirements 10 Installing the Burner 12 Gas Supply 12 Stone Configuration 14 Operating Instructions 17 Maintenance 19 Troubleshooting 20 Parts List 22 Warranty 23 ...

Page 3: ...appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids 7 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 8 Solid fuels shall not be burned in a fireplace where ...

Page 4: ...ctions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindie L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz AVERTISSEMENT Risque de dommages ou de blessures si les pièces ne sont pas installées confor mément à ces schémas et ou si des pièces autres que celles spécifiqu...

Page 5: ...age Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier AVERTISSEMENT Une installation un réglage une modification une réparation ou un entretien mal effectué puet causer des dommages matériels ou des blessures Voir la notice de l utilisateur qui accompagne l appareil Pour de ...

Page 6: ... Supply Pressure 7 0 1 7 kPa 13 0 3 2 kPa Minimum Supply Pressure 4 0 1 0 kPa 11 0 2 7 kPa Orifice Size 6 Port 55 DMS 48 DMS Canadian Efficiency P 4 32 39 High Fire Input 42 000 BTU hr 43 500 BTU hr Low Fire Input 27 000 BTU hr 27 000 BTU hr Gas Stones with 24 Fusion Basket Gas Stones with 30 Fusion Basket ...

Page 7: ...7 SPECIFICATIONS and DIMENSIONS A 12 00 17 84 0 62 5 38 1 54 6 70 17 84 3 08 1 00 12 00 5 38 3 31 3 08 3 31 Dimension A 24 30 ...

Page 8: ...8 0 75 0 75 3 00 22 50 Room Rear of Fireplace SPECIFICATIONS and DIMENSIONS Premise gas supply should terminate within shaded area shown on plan view above ...

Page 9: ...s and supplies Adjustable wrench Phillips and straight blade screwdrivers Tape measure and framing square Safety glasses and gloves Manometer Leak detection fluid non corrosive or gas detector Reset the Gas Stones with Fusion Basket before the first fire See Resetting the System under OPERATING INSTRUCTIONS for details NOTE ...

Page 10: ...sket is behind the fireplace lintel See Figure 1 A minimum free opening of 50 square inches must be provided by the chimney or damper to vent the flue gases The chimney damper must be fixed with the clamp provided to maintain the minimum free opening See Figure 2 Note The Commonwealth of Massachusetts requires that the damper be removed or welded in the fully open position Clamp Figure 2 Figure 1 ...

Page 11: ...NTEL CLEARANCES 12 0 5 0 Existing fireplace opening Top of existing fireplace opening Combustible mantels may be no closer to the fireplace opening than the distances shown in the Figure 2a side view above Figure 2a ...

Page 12: ...hat system at test pressures in excess of psi 3 5 kPa The Gas Stones with Fusion Basket must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or less than psi 3 5 kPa GAS SUPPLY INSTALLING THE BURNER Warning This product must be installed by a licensed plumber or gas fitter when installed...

Page 13: ...nd apply a soapy water solution to all the fittings to check for gas leaks Never use a flame to test for leaks If you are installing a propane burner check that the air shutter see Figure 5 is in the open position Replace the burner in the burner module Ensure that the burner inlet tube is in the shutter box Air shutter shown in the open position for propane only Figure 5 Figure 6 ...

Page 14: ...n Slight differences in the placements are acceptable When using the stones and embers begin by placing one layer of the embers evenly over the entire burner top as shown in Figure 7 Sort your stones by size into sixteen small three medium and four large Place a row of six small stones along the rear edge of the burner as shown in Figure 8 Figure 7 S S S S S S Figure 8 ...

Page 15: ...and three small stones on the burner as shown in Figure 9 Then place two medium and four small stones along the front edge of the burner as shown in Figure 10 Figure 9 S S S S S S S S S L L Figure 10 L L S S S S S S S S S S S S M M S ...

Page 16: ...16 Finally place the remaining two large one medium and three small stones on top as shown in Figure 11 Figure 11 S M L S S L L L M M S S S S S S S S S S S S S ...

Page 17: ...s If you cannot reach your gas supplier call the fire department C Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con trol which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result causing property dam...

Page 18: ...l continue until main gas flows and the burner is lit If the pilot or burner does not light go back to Step 3 above 6 Use the LARGE FLAME Ç and SMALL FLAME È buttons to adjust the flame height LIGHTING THE FIRE OFF LARGE FLAME SMALL FLAME SET RESETTING THE SYSTEM This procedure resets the system as well as pairs the remote and the receiver It is only needed to be performed once but can be done as ...

Page 19: ...ving only the pilot ignited Fully Extinguishing the Appliance From any heat setting press the OFF button for a few seconds This will cause the burner to fully extinguish The system has a safety interlock which will not allow the ignition until the interlock rests This may take a few minutes The appliance should be shut off completely using the OFF button on the handset and not left on pilot only e...

Page 20: ...use a vacuum cleaner to clean the stones Clean the burner surface with a brush Replace the components according to the instructions starting on page 11 of this manual Inspecting the Chimney An inspection of the chimney should be made as part of the annual service appointment The chimney must have no blockage and be in good repair Replacing the Batteries With all parts of the fireplace at room temp...

Page 21: ... the transmitter and reprogram code as above 1 Secure wire 2 Replace receiver and reprogram code as above 3 Straighten pins on 8 wire connector 4 Replace valve 1 Purge the line or start ignition several times 2 Check spark gap check wiring connec tion Check for spark in location along cable 3 Replace valve Do not over tighten the thermocouple POSSIBLE CAUSE 1 Receiver must learn new code 2 Dead ba...

Page 22: ...ween the spade connector closest to the thermocouple and thermocouple tube itself The reading should be 21 30 mV 2 Replace thermocouple 3 Confirm regulator pressure and sizing Replace if necessary 4 Replace valve Do not over tighten the thermocouple 1 Replace batteries 1 Turn manual override knob to ON position 2 Turn flame to high fire by pressing the UP button on remote control 3 Confirm regulat...

Page 23: ...those in the picture above PARTS LIST Burner Module NG GSBM NG 01 Burner Module LP GSBM LP 01 Stone Kit VPK 01 Pilot Assembly VPA 01 Fusion Basket VSB 01 For replacement parts and customer service contact EUROPEAN HOME 1 781 324 8383 ...

Page 24: ... PRODUCT INSTALLATION RECORD Installer Please complete this form Customer Please retain this information Purchased From Date of Purchase Installed By Date of Installation Fireplace Serial Number Fuel Type ...

Page 25: ...25 NOTES ...

Page 26: ...26 rev 160217 EUROPEAN HOME a division of Europa Ja Inc 376 Washington Street Suite 203 Malden MA 02148 www europeanhome com ...

Reviews: