11
ELECTRICAL REQUIREMENTS
VBM Burner
The Vision Gas Fireplace with a
VBM
burner uses a receiver and remote control for its burner opera-
tion. The remote control comes with a 9V battery and the receiver is powered by a 120V AC wall
adapter.
This installation must provide an approved 120V AC wall receptacle to be placed within the six foot
cord limit of the wall adapter.
The receiver should be powered by either the wall adapter or 4AA batteries - not both.
Batteries do
not provide an electrical backup for the wall adapter. Using batteries in combination with the
wall adapter can damage the receiver.
24VBM Burner
The Vision Gas Fireplace with a
24VBM
burner is powered by a 24V AC transformer (included) which
must be wired to a 120V AC branch circuit. The 24V AC side of the transformer is switched with a
customer-supplied, 24V AC-rated switch.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation.
This appliance must be electrically grounded in accordance with local codes, or, in the absence of local codes, with either
the National Electrical Code ANSI/NFPA 70, for installations in the U.S. or the Canadian Electrical Code, CSA C22. 1 for
installations in Canada.
Electrical work should only be performed by a qualified, licensed electrician. Electric power must be off when making
connections or performing any service.
All wiring shall be in compliance with all local, city, and state codes.
WARNING