8
SPECIFICATIONS and DIMENSIONS
Natural Gas
Propane (LP)
Manifold Pressure:
4.0” (1.0 kPa)
10.0” ( 2.5 kPa)
Maximum Supply Pressure:
7.0” (1.7 kPa)
13.0” (3.2 kPa)
Minimum Supply Pressure:
4.0” (1.0 kPa)
11.0” (2.7 kPa)
Orifice Size:
6 Port #55 DMS
#48 DMS
Canadian Efficiency P.4:
32%
39%
Input:
High Fire
42,000 BTU/hr.
43,500 BTU/hr.
Low Fire*
27,000 BTU/hr.
27,000 BTU/hr.
*
VBM
burner ONLY
All dimensions are in inches.
VBM Wall Adapter Specifications
Input Voltage:
120V AC
Input Power:
9 W
Output Voltage:
6V DC
Output Current:
500 mA
Size:
3.1”H x 2”W x 1.7”D
Output Cord Length:
6 Feet
Agency Approvals:
UL, CSA
24VBM Electrical Rating
Voltage:
120V AC, 60 Hz
Current: 0.8A
Agency Approvals:
CSA