rev.110331
All service and repairs should be performed by a qualified agency.
All spare parts, optional fans, and optional trim finishes are available from your local
dealer or the manufacturer.
Maintenance
Troubleshooting
The following is a troubleshooting chart of possible problems:
PROBLEM
CORRECTIVE ACTION
Noisy Pilot Flame
Locate pilot adjustment screw on the front of
the gas control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite
Disconnect remote wires and try to light
pilot. If pilot now works, remote connections
are faulty. Check wiring diagram, below.
Main burner will
1. Check wiring
not light
2. Check wall switch for proper connection.
3. Check pilot burner. If extinguished:
a. Allow fireplace to cool, then try to relight.
b. If condition persists, call a qualified
service person.
Troubleshooting
To reset the SIT System, refer to schematic, below
and:
1. Locate the connection to the battery backup and
disconnect it.
2. Locate the AC/DC wall transformer and unplug
the connector.
Wait for 120 seconds and re-connect the wall
transformer and battery backup.
If your fireplace still does not operate correctly,
consult your installer.