40
2.8. Configuration Menu
To acess the configuration menu,
press the OFF button on the remote control for 40 seconds. During
this time the screen may go blank, this is normal. After 40 seconds, the Configuration menu appears. This is a
list of the settings that can be changed in the configuration menu:
Pairing:
This feature establishes communication between the remote and the fire-
place. Pairing will not be required unless communication is lost or, you have a new
remote control. If pairing is required it must be done on channel A (go to the last
option in the configuration menu by pressing and select channel A).
After that, go to pairing option again and press the select button (middle button)
and when off is highlighted, press the change button (left button) off becomes on.
Once the pairing is on, you have 20 seconds to push (press and release) the button
S1 (yellow) in the control unit.
Once this operation is done, you hear a beep in the control unit and on the control
unit will appear:
To return to the home screen press the back button until you get to main screen.
PS: If pairing has been attempted previously and has not been achieved, try the follow-
ing:
- Press and hold the OFF button for 40 seconds.
- Set the channel on channel A.
- Select On in the pairing setting.
- Unplug the batteries from the control unit (wait 10 seconds) and plug the
batteries back in.
- Once the valve has finished moving, repeatedly push (press and release) the S1 but-
ton (yellow button on the control unit), until you hear the beep that confirms that pair-
ing has taken place
.
Thermostat:
This option enables or disables the auto thermostat mode. To enable it, select Yes. To disable it
select No.
Gap Temp:
this option refers to the tolerance between the desired temperature and the current one. If the dif-
ference is greater than this gap temperature setting, the flame level increases. For example: the desired tem-
perature is set at 20°C and the current temperature is 18°C:
• If the Gap Temp is 0.5°C: Flame level will go to maximum level because the difference is 2°C.
• If the Gap Temp is 1°C: Flame level will go to medium level as difference of 2°C is two times the gap set-
ting.
If the Gap Temp is 2°C: Flame level will go to minimum level as the difference of 2°C is equal to the gap
setting.
COPRECI R-emotion CONTROL SYSTEM