Always check with your state board for required cleaning and disinfecting procedures. 

It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of the day, 
and once a week for overnight cleaning.  Regular cleaning will help keep your pedicure spa in good working condition. 
Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection. To clean your pedicure spa 
equipped with Pipe-Free technology, follow these easy steps.  

 

Procedures for Cleaning and Disinfecting Pipe-Free Pedicure spas 

After use upon each patron, each Pipe-Free Pedicure spa shall be cleaned and disinfected in the following sequential 
manner: 

(1) 

All water shall be drained from the spa basin

(2) 

Remove Pipe-Free Cover by turning clockwise.

   

(3)   

Using handheld sprayer, rinse side walls of basin, pipe free jet and pipe free cover of all residue and debris. 

(4) 

Scrub all visible residue from the Pipe-Free Cover, inside walls of the basin, and/or other components and the 
areas behind or under each with a clean brush and liquid soap (labeled as such on soap product) and water. 
Rinse with clean water.

  

(4) 

Reinsert the properly cleaned Pipe-Free Cover over jet.  

Disinfecting with water filled basin directions:

 

(1) 

Refill the basin with clean water and circulate the correct amount (read the label for mixing instructions) of the 
EPA-registered hospital-liquid disinfectant, which the label claims is a bactericide, fungicide, and virucide, 
through the basin for at least 10 minutes.

 

(2) 

Drain, rinse and wipe the basin dry with a clean paper towel.

 

(3) 

Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each cleaning, 
initials of the person who completed the procedure, and shall indicate that the cleaning was done after a client.

 

Disinfecting with Ready to Use (RTU) products and surface saturation directions: 

(1) 

Spray to saturate inside of basin, all basin walls and area inside Pipe-Free Jet area with EPA registered 
disinfectant and allow sitting for at least 10 minutes.

 

(2) 

Submerged Pipe-Free Cover in container of EPA registered disinfectant for at least 10 minutes OR spray Pipe-
Free Cover to saturate with EPA registered disinfectant and lay inside basin for a minimum of 10 minutes

(3)  

Rinse and wipe the basin dry with a clean paper towel. Follow step (4) above.

 

 

At the end of every day and after performing the procedures provided in subsection (b) (1 through 6) and after the last 
client, each pipe-free pedicure spa shall be cleaned and disinfected in the following sequential manner: 

(1) 

Fill the basin with warm water and detergent (labeled as such on detergent product) and circulate the detergent 
through the spa system for at least 10 minutes.

 

(2) 

Drain the detergent solution and rinse the basin.

  

(3) 

Refill the basin with clean water and circulate the correct amount (read the label for mixing instructions) of the 
EPA-registered hospital-liquid disinfectant which the label claims is a bactericide, fungicide, and virucide, 
through the basin for at least 10 minutes.

  

(4) 

Drain, rinse and wipe the basin dry with a clean paper towel.

 

(5) 

Allow the basin to dry completely

(6) 

Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each cleaning, 
initials of the person who completed the procedure, and shall indicate that the cleaning was done at the end of 
the day

.  

 

At least once each week, after completing the procedures provided in subsection (c) (1 through 3), and the disinfectant 
solution in each pipe-free pedicure spa shall not be drained and the following sequential procedures shall be followed:  

(1) 

The unit shall be turned off and the disinfecting solution shall be left in the unit undisturbed for 6 to 10 hours

(2) 

After the disinfectant solution has been sitting between 6 to 10 hours, rinse and wipe the basin dry with a clean 
paper towel.

 

(3) 

Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each cleaning, 
initials of the person who completed the procedure, and shall indicate that the cleaning was done weekly. 

The pedicure-cleaning log shall be made available upon request by either a patron or a state board representative. 

 

A violation of this section may result in an administrative fine and/or disciplinary action.

 

 

CAUTION: Cleaning products that contain abrasives can damage the pedicure spa.  Use only non-abrasive products to 
clean your spa. 

Summary of Contents for Espresso Spa

Page 1: ......

Page 2: ...expenses incurred by the Customer or any third party including labor or material during investigation removal or reinstallation of the Pedicure Spa or any defective components or parts To any damage t...

Page 3: ...not limited to obligations or liabilities arising out of breach of contract or warranty negligence or other tort or any theory of strict liability with respect to the Pedicure Spa or parts or compone...

Page 4: ...OWNERS MANUAL For Espresso Spa IMPORTANT INFORMATION Serial Number Work Order Number Installed by Installation Date The serial number and work order number are located under the rear access panel Rem...

Page 5: ...DANGER 7 WARNINGS 7 IMPORTANT REQUIREMENTS 8 HEALTH RISK WARNING 8 PEDICURE SPA SPECIFICATIONS 9 INSTALLATION ASSEMBLY INSTRUCTIONS 10 PEDICURE PRODUCT GUIDELINES 16 PIPE FREE SPA CLEANING AND DISINFE...

Page 6: ...w all of your state and local codes Many require a vacuum breaker be added to the water inlet lines which is not supplied by European Touch When using an electrical appliance basic precautions should...

Page 7: ...control setting a Do not use on Infants Invalids Sleeping or unconscious person b Do not use on Insensitive skin Person with poor blood circulation Note Check the skin in contact with the heated area...

Page 8: ...e spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser See limited warranty regarding incidental or consequential exclusions page 2 HEALTH RI...

Page 9: ...pholstery Polyurethane Power Source 110V AC 2 75 Amps 60 Hz GFCI Protected X Caution Pedicure spa must be installed by a licensed electrician and a licensed plumber conforming to all local and nationa...

Page 10: ...ceived Be sure that you have received all components The components should include If you do not have any of the above components please contact EUROPEAN TOUCH s Technical Support Department at 1 800...

Page 11: ...6 or 5mm Allen Wrench Crescent Wrench Channel Locks Wrench STEP 1 Begin by locating the spa in the appropriate place and position all components near STEP 2 Turn the Basin Assembly and the Extension A...

Page 12: ...hole at the back of the extension STEP 5 Uncoil the hoses and cords coming from the basin and plug in the cords into the power strip STEP 6 Run the stainless steel Hot and Cold hoses underneath the ex...

Page 13: ...xtension Remove the brass nut rubber o ring and nylon ring from brass bulkhead fitting Pass the bulkhead fitting through the small left hole in the back of the extension Place the rubber o ring then t...

Page 14: ...sure to add a vacuum breaker if required by your specific plumbing codes STEP 10 Take the transformer that is shipped with the chair and plug that into the power strip and run the cord underneath the...

Page 15: ...ushion to the armrests using the supplied screws Place supplied caps into holes of the armrests after assembly is complete STEP 13 Plug transformer cord into bottom of back cushion Plug wire from back...

Page 16: ...ng a foaming agent this will cause excessive foam It has been determined that products containing non dissolving abrasives such as sand and sea salts will not harm the internal component structure of...

Page 17: ...minutes 2 Submerged Pipe Free Cover in container of EPA registered disinfectant for at least 10 minutes OR spray Pipe Free Cover to saturate with EPA registered disinfectant and lay inside basin for a...

Page 18: ...AILY CLEANING LOG Pedicure Spa Date Time Initials After Client End of Day Weekly For your convenience on pages 19 20 we are providing daily cleaning log sheets which you can remove from the manual for...

Page 19: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 19 of 26 DAILY CLEANING LOG Pedicure Spa Date Time Initials After Client End of Day Weekly...

Page 20: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 20 of 26 DAILY CLEANING LOG Pedicure Spa Date Time Initials After Client End of Day Weekly...

Page 21: ...ME 1 7 30010227 GASKET STOPPER RINATO 1 8 30020201 THREADED WASTE BOLT 1 9 30020202 STRAINER DRAIN CHROME 1 10 30010235 GASKET RUBBER DRAIN TOP SIDE 1 11 30010225 WASTE SHOE 1 Power Drain Pump Assembl...

Page 22: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 22 of 26 Full Assembly...

Page 23: ...ON OFF TWO POSITION CT 1 14 30010221 GASKET BUTTON SWITCH 1 15 31041401 CABLE WATER MOVEMENT CT DROP IN BASIN 1 16 39150005 KIT MANUAL FULL YU SPA 1 17 39031501 LABEL ET LOGO ESPRESSO 1 18 15000006 G...

Page 24: ...BUSHING REDUCING 1 1 4 IN X 1 2 IN 1 5 08010004 NIPPLE PVC FTG PDP 1 6 08040001 PUMP PDP 110V 1 9 15130022 HOSE 48 IN RUBBER 1 10 15130029 CLAMP TUBE 6 1 2 IN 1 11 06130025 SCREW DRYWALL 8 X 3 4 BLAC...

Page 25: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 25 of 26 HISTORY AND NOTES...

Page 26: ...EUROPEAN TOUCH 8301 W Parkland Court Milwaukee WI 53223 Phone Number 1 414 357 7016 Toll Free 1 800 626 6912 Fax 1 414 357 6360 Web Site www europeantouch com Email info europeantouch com...

Reviews:

Related manuals for Espresso Spa