background image

 

 

Document ID: 39080000 

Rev: C 

Technical Support: 1-800-626-6912 

       Page 9 of 26 

 

 

P

EDICURE 

S

PA 

S

PECIFICATIONS

 

 
Hot and cold water supply lines required 

(hot and cold shut offs may be installed under pedicure spa base)  

 
SHIPPING INFORMATION 
Dimensions:

 

48”L (165cm) x 40W (84cm) x 41”H (104cm) – includes Spa, carton, and pallet 

 

Weight:

 

140 lbs. (117 kg) - includes spa, carton, pallet

 

 
SPA INFORMATION 
Overall Dimensions:   

66"L (152.4cm) x 27”W (68.6cm) x 49"H (125cm) 

 
Minimum Area Required For Chair Movement:      
 

66”L (168cm) x 40”W (101cm) x 49"H (125cm) 

 
Empty Weight (Complete): 

125lbs (57kg) 

 

Water Fill Line Capacity: 

4.5-5.5 U.S. gallons to accommodate 5’1” to 6’8” Clients 

 

Whirlpool Pump Motor: 

1/6 HP, 110V, 60Hz 

 

Seat Upholstery: 

Polyurethane 

 
Power Source: 

110V AC, 2.75 Amps, 60 Hz (GFCI Protected) 

  

X

 

Caution: Pedicure spa must be installed by a licensed electrician and a licensed plumber, 
conforming to all local and national electrical codes 

 
Construction:

 

Linear Low Density Polyethylene (LLDPE)

 

 

Pipe-Free

®

 Technology: 

No closed loop circulating pipes, fully drained, easy to clean and sanitize. 

 

Electrical Switches: 

On/Off switch for water movement motor.  A single hand-held, low voltage 
remote control of the massage motors.  On/Off for drain is optional. 

 

Compliances: 

Tested according to UL 1951:2008, CAN/CSA C22.8 No. 68-92:2006, 
ASME/ANSI A112.19.7M:1995, ASTM D2564-84 

 
 

Limited Warranty:

 

One (1) year on parts from date of shipment. Labor is not included.

 

 

 

NOTE:  Due to our policy of continuous improvements, all specifications are subject to change without notice. 

All dimensions and weights are approximate

Summary of Contents for Espresso Spa

Page 1: ......

Page 2: ...expenses incurred by the Customer or any third party including labor or material during investigation removal or reinstallation of the Pedicure Spa or any defective components or parts To any damage t...

Page 3: ...not limited to obligations or liabilities arising out of breach of contract or warranty negligence or other tort or any theory of strict liability with respect to the Pedicure Spa or parts or compone...

Page 4: ...OWNERS MANUAL For Espresso Spa IMPORTANT INFORMATION Serial Number Work Order Number Installed by Installation Date The serial number and work order number are located under the rear access panel Rem...

Page 5: ...DANGER 7 WARNINGS 7 IMPORTANT REQUIREMENTS 8 HEALTH RISK WARNING 8 PEDICURE SPA SPECIFICATIONS 9 INSTALLATION ASSEMBLY INSTRUCTIONS 10 PEDICURE PRODUCT GUIDELINES 16 PIPE FREE SPA CLEANING AND DISINFE...

Page 6: ...w all of your state and local codes Many require a vacuum breaker be added to the water inlet lines which is not supplied by European Touch When using an electrical appliance basic precautions should...

Page 7: ...control setting a Do not use on Infants Invalids Sleeping or unconscious person b Do not use on Insensitive skin Person with poor blood circulation Note Check the skin in contact with the heated area...

Page 8: ...e spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser See limited warranty regarding incidental or consequential exclusions page 2 HEALTH RI...

Page 9: ...pholstery Polyurethane Power Source 110V AC 2 75 Amps 60 Hz GFCI Protected X Caution Pedicure spa must be installed by a licensed electrician and a licensed plumber conforming to all local and nationa...

Page 10: ...ceived Be sure that you have received all components The components should include If you do not have any of the above components please contact EUROPEAN TOUCH s Technical Support Department at 1 800...

Page 11: ...6 or 5mm Allen Wrench Crescent Wrench Channel Locks Wrench STEP 1 Begin by locating the spa in the appropriate place and position all components near STEP 2 Turn the Basin Assembly and the Extension A...

Page 12: ...hole at the back of the extension STEP 5 Uncoil the hoses and cords coming from the basin and plug in the cords into the power strip STEP 6 Run the stainless steel Hot and Cold hoses underneath the ex...

Page 13: ...xtension Remove the brass nut rubber o ring and nylon ring from brass bulkhead fitting Pass the bulkhead fitting through the small left hole in the back of the extension Place the rubber o ring then t...

Page 14: ...sure to add a vacuum breaker if required by your specific plumbing codes STEP 10 Take the transformer that is shipped with the chair and plug that into the power strip and run the cord underneath the...

Page 15: ...ushion to the armrests using the supplied screws Place supplied caps into holes of the armrests after assembly is complete STEP 13 Plug transformer cord into bottom of back cushion Plug wire from back...

Page 16: ...ng a foaming agent this will cause excessive foam It has been determined that products containing non dissolving abrasives such as sand and sea salts will not harm the internal component structure of...

Page 17: ...minutes 2 Submerged Pipe Free Cover in container of EPA registered disinfectant for at least 10 minutes OR spray Pipe Free Cover to saturate with EPA registered disinfectant and lay inside basin for a...

Page 18: ...AILY CLEANING LOG Pedicure Spa Date Time Initials After Client End of Day Weekly For your convenience on pages 19 20 we are providing daily cleaning log sheets which you can remove from the manual for...

Page 19: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 19 of 26 DAILY CLEANING LOG Pedicure Spa Date Time Initials After Client End of Day Weekly...

Page 20: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 20 of 26 DAILY CLEANING LOG Pedicure Spa Date Time Initials After Client End of Day Weekly...

Page 21: ...ME 1 7 30010227 GASKET STOPPER RINATO 1 8 30020201 THREADED WASTE BOLT 1 9 30020202 STRAINER DRAIN CHROME 1 10 30010235 GASKET RUBBER DRAIN TOP SIDE 1 11 30010225 WASTE SHOE 1 Power Drain Pump Assembl...

Page 22: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 22 of 26 Full Assembly...

Page 23: ...ON OFF TWO POSITION CT 1 14 30010221 GASKET BUTTON SWITCH 1 15 31041401 CABLE WATER MOVEMENT CT DROP IN BASIN 1 16 39150005 KIT MANUAL FULL YU SPA 1 17 39031501 LABEL ET LOGO ESPRESSO 1 18 15000006 G...

Page 24: ...BUSHING REDUCING 1 1 4 IN X 1 2 IN 1 5 08010004 NIPPLE PVC FTG PDP 1 6 08040001 PUMP PDP 110V 1 9 15130022 HOSE 48 IN RUBBER 1 10 15130029 CLAMP TUBE 6 1 2 IN 1 11 06130025 SCREW DRYWALL 8 X 3 4 BLAC...

Page 25: ...Document ID 39080000 Rev C Technical Support 1 800 626 6912 Page 25 of 26 HISTORY AND NOTES...

Page 26: ...EUROPEAN TOUCH 8301 W Parkland Court Milwaukee WI 53223 Phone Number 1 414 357 7016 Toll Free 1 800 626 6912 Fax 1 414 357 6360 Web Site www europeantouch com Email info europeantouch com...

Reviews: