Always check with your state board for required cleaning and disinfecting procedures. 

It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of 
the day, and once a week for overnight cleaning.  Regular cleaning will help keep your pedicure spa in good 
working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection. 
To clean your pedicure spa equipped with Clean Touch technology, follow these easy steps.  

 

Procedures for Cleaning and Disinfecting Pipe-Free Pedicure spas 

After use upon each patron, each Pipe-Free Pedicure spa shall be cleaned and disinfected in the following 
sequential manner: 

(1)  All water shall be drained from the spa basin. 
(2)  Remove 2 piece inlet housing & impeller. 
(3)  Scrub all visible residue from the inlet housing, impeller, inside walls of the basin, and/or other 

components and the areas behind or under each with a clean brush and liquid soap (labeled as such 
on soap product) and water. Rinse with clean water.  

(4)  Reinsert the properly cleaned inlet housing & impeller,  
(5)  Refill the basin with clean water and circulate the correct amount (read the label for mixing 

instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a bactericide, 
fungicide, and virucide, through the basin for at least 10 minutes. 

(6)  Drain, rinse and wipe the basin dry with a clean paper towel. 
(7)  Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each 

cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was 
done after a client. 

 
At the end of every day and after performing the procedures provided in subsection (b) (1 through 6) and after 
the last client, each pipe-free pedicure spa shall be cleaned and disinfected in the following sequential manner: 

(1)  Fill the basin with warm water and detergent (labeled as such on detergent product) and circulate the 

detergent through the spa system for at least 10 minutes. 

(2)  Drain the detergent solution and rinse the basin.  
(3)  Refill the basin with clean water and circulate the correct amount (read the label for mixing 

instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a bactericide, 
fungicide, and virucide, through the basin for at least 10 minutes.  

(4)  Drain, rinse and wipe the basin dry with a clean paper towel. 
(5)  Allow the basin to dry completely. 
(6)  Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each 

cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was 
done at the end of the day.  

 
At least once each week, after completing the procedures provided in subsection (c) (1 through 3), and the 
disinfectant solution in each pipe-free pedicure spa shall not be drained and the following sequential 
procedures shall be followed:  

(1)  The unit shall be turned off and the disinfecting solution shall be left in the unit undisturbed for 6 to 10 

hours. 

(2)  After the disinfectant solution has been sitting between 6 to 10 hours, rinse and wipe the basin dry 

with a clean paper towel. 

(3)  Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each 

cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was 
done weekly. 

The pedicure-cleaning log shall be made available upon request by either a patron or a state board 
representative.

 

 

A violation of this section may result in an administrative fine and/or disciplinary action.

 

 

CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Use only   non-abrasive 
products to clean your spa 
 

Summary of Contents for Rinato SPA

Page 1: ...Document ID 30080001 Rev G Technical Support 1 800 626 6912 Page 1 of 18...

Page 2: ...ouch preferred service provider provided however that labor is not covered for those parts listed on attached Exhibit A as provided below Cost of repair by any non authorized service provider is not r...

Page 3: ...ine or other chemicals will void this limited warranty except to the extent such use is required by the provisions applicable law Avoidance of the use of ionic detox machines that submit any metallic...

Page 4: ...O BE DEFECTIVE THIS LIMITED WARRANTY GIVES THE CUSTOMER SPECIFIC LEGAL RIGHTS THE CUSTOMER MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY BY EACH JURISDICTION Should your Pedicure Spa require service due t...

Page 5: ...A 53223 COMPLIANCE LISTINGS To the following standard s ANSI Z124 1 2 ASME A112 18 1 ASME A112 18 2 ASME A112 19 7 CSA B45 10 CSA B125 1 CSA B125 2 UL 60335 1 UL 1647 CAN CSA E60335 2 32 CAN CSA E6033...

Page 6: ...or Rinato Spa IMPORTANT INFORMATION Serial Number Work Order Number Installed by Installation Date The serial number and work order number are located under the seat bottom cushion on the seat track p...

Page 7: ...MATION 6 INTRODUCTION 8 IMPORTANT SAFETY INSTRUCTIONS 8 DANGER 9 WARNINGS 9 IMPORTANT REQUIREMENTS 10 HEALTH RISK WARNING 10 PEDICURE SPA SPECIFICATIONS 11 REMOTE CONTROL CONFIGURATIONS 12 WIRED SOUND...

Page 8: ...PM CST After hours calls are recorded and attended to the next business day IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance basic precautions should always be followed including the...

Page 9: ...rson b Do not use on Insensitive skin Person with poor blood circulation Note Check the skin in contact with the heated area of the appliance frequently to reduce the risk of blistering 4 Excessive wa...

Page 10: ...e spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser See limited warranty regarding incidental or consequential exclusions page 2 HEALTH RI...

Page 11: ...Hz GFCI Protected X Caution Pedicure spa must be installed by a licensed electrician and a licensed plumber conforming to all local and national electrical codes Construction Metal Frame with Acrylic...

Page 12: ...Back Tilt backward or forward LEDs indicate Vibration feature is activated Turns Vibration feature On Off LED indicates Vibration feature is activated Adjusts vibration intensities up or down LED indi...

Page 13: ...of 18 WIRED SOUND OPTION 1 8 3 5mm Phone Plug Cable Plug into any MP3 Player or IPOD that has a 1 8 3 5mm Phone Jack 1 8 3 5mm Phone Jack Plug in Headphones or Portable Speakers Stowe away the end of...

Page 14: ...nts Do not use any products containing a foaming agent this will cause excessive foam It has been determined that products containing non dissolving abrasives such as sand and sea salts will not harm...

Page 15: ...rming the procedures provided in subsection b 1 through 6 and after the last client each pipe free pedicure spa shall be cleaned and disinfected in the following sequential manner 1 Fill the basin wit...

Page 16: ...Document ID 30080001 Rev G Technical Support 1 800 626 6912 Page 16 of 18 HISTORY AND NOTES...

Page 17: ...Document ID 30080001 Rev G Technical Support 1 800 626 6912 Page 17 of 18 HISTORY AND NOTES...

Page 18: ...EUROPEAN TOUCH 8301 W Parkland Court Milwaukee WI 53223 Phone Number 1 414 357 7016 Toll Free 1 800 626 6912 Fax 1 414 357 6360 Web Site www europeantouch com Email info europeantouch com...

Reviews: