Document ID: 30080001
Rev: G
Technical Support: 1-800-626-6912
Page 15 of 18
C
LEAN
T
OUCH
™
P
IPE
-F
REE
S
PA
C
LEANING AND
D
ISINFECTING
P
ROCEDURES
Always check with your state board for required cleaning and disinfecting procedures.
It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of
the day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in good
working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection.
To clean your pedicure spa equipped with Clean Touch technology, follow these easy steps.
Procedures for Cleaning and Disinfecting Pipe-Free Pedicure spas
After use upon each patron, each Pipe-Free Pedicure spa shall be cleaned and disinfected in the following
sequential manner:
(1) All water shall be drained from the spa basin.
(2) Remove 2 piece inlet housing & impeller.
(3) Scrub all visible residue from the inlet housing, impeller, inside walls of the basin, and/or other
components and the areas behind or under each with a clean brush and liquid soap (labeled as such
on soap product) and water. Rinse with clean water.
(4) Reinsert the properly cleaned inlet housing & impeller,
(5) Refill the basin with clean water and circulate the correct amount (read the label for mixing
instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a bactericide,
fungicide, and virucide, through the basin for at least 10 minutes.
(6) Drain, rinse and wipe the basin dry with a clean paper towel.
(7) Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each
cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was
done after a client.
At the end of every day and after performing the procedures provided in subsection (b) (1 through 6) and after
the last client, each pipe-free pedicure spa shall be cleaned and disinfected in the following sequential manner:
(1) Fill the basin with warm water and detergent (labeled as such on detergent product) and circulate the
detergent through the spa system for at least 10 minutes.
(2) Drain the detergent solution and rinse the basin.
(3) Refill the basin with clean water and circulate the correct amount (read the label for mixing
instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a bactericide,
fungicide, and virucide, through the basin for at least 10 minutes.
(4) Drain, rinse and wipe the basin dry with a clean paper towel.
(5) Allow the basin to dry completely.
(6) Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each
cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was
done at the end of the day.
At least once each week, after completing the procedures provided in subsection (c) (1 through 3), and the
disinfectant solution in each pipe-free pedicure spa shall not be drained and the following sequential
procedures shall be followed:
(1) The unit shall be turned off and the disinfecting solution shall be left in the unit undisturbed for 6 to 10
hours.
(2) After the disinfectant solution has been sitting between 6 to 10 hours, rinse and wipe the basin dry
with a clean paper towel.
(3) Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each
cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was
done weekly.
The pedicure-cleaning log shall be made available upon request by either a patron or a state board
representative.
A violation of this section may result in an administrative fine and/or disciplinary action.
CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Use only non-abrasive
products to clean your spa
Summary of Contents for Rinato SPA
Page 1: ...Document ID 30080001 Rev G Technical Support 1 800 626 6912 Page 1 of 18...
Page 16: ...Document ID 30080001 Rev G Technical Support 1 800 626 6912 Page 16 of 18 HISTORY AND NOTES...
Page 17: ...Document ID 30080001 Rev G Technical Support 1 800 626 6912 Page 17 of 18 HISTORY AND NOTES...