70080000 Manual Sogno DreamWave Spa 

Rev A 

Revision Date: 25 March 2010 

Page 34 of 42 

C

LEAN 

T

OUCH

 

P

IPE

-F

REE 

S

PA 

C

LEANING AND 

D

ISINFECTING 

P

ROCEDURES

 

Always check with your state board for required cleaning and disinfecting procedures. 

It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of 
the day, and once a week for overnight cleaning.  Regular cleaning will help keep your pedicure spa in good 
working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection. 
To clean your pedicure spa equipped with Clean Touch technology, follow these easy steps.  

 

Procedures for Cleaning and Disinfecting Pipe-Free Pedicure spas 

After use upon each patron, each Pipe-Free Pedicure spa shall be cleaned and disinfected in the following 
sequential manner: 

(1)  All water shall be drained from the spa basin. 
(2)  Remove 2 piece inlet housing & impeller. 
(3)  Scrub all visible residue from the inlet housing, impeller, inside walls of the basin, and/or other 

components and the areas behind or under each with a clean brush and liquid soap (labeled as such 
on soap product) and water. Rinse with clean water.  

(4)  Reinsert the properly cleaned inlet housing & impeller,  
(5)  Refill the basin with clean water and circulate the correct amount (read the label for mixing 

instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a bactericide, 
fungicide, and virucide, through the basin for at least 10 minutes. 

(6)  Drain, rinse and wipe the basin dry with a clean paper towel. 
(7)  Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each 

cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was 
done after a client. 

At the end of every day and after performing the procedures provided in subsection (b) (1 through 6) and after 
the last client, each pipe-free pedicure spa shall be cleaned and disinfected in the following sequential manner: 

(1)  Fill the basin with warm water and detergent (labeled as such on detergent product) and circulate the 

detergent through the spa system for at least 10 minutes. 

(2)  Drain the detergent solution and rinse the basin.  
(3)  Refill the basin with clean water and circulate the correct amount (read the label for mixing 

instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a bactericide, 
fungicide, and virucide, through the basin for at least 10 minutes.  

(4)  Drain, rinse and wipe the basin dry with a clean paper towel. 
(5)  Allow the basin to dry completely. 
(6)  Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each 

cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was 
done at the end of the day.  

At least once each week, after completing the procedures provided in subsection (c) (1 through 3), and the 
disinfectant solution in each pipe-free pedicure spa shall not be drained and the following sequential 
procedures shall be followed:  

(1)  The unit shall be turned off and the disinfecting solution shall be left in the unit undisturbed for 6 to 10 

hours. 

(2)  After the disinfectant solution has been sitting between 6 to 10 hours, rinse and wipe the basin dry 

with a clean paper towel. 

(3)  Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each 

cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was 
done weekly. 

The pedicure-cleaning log shall be made available upon request by either a patron or a state board 
representative. 

A violation of this section may result in an administrative fine and/or disciplinary action. 

 

CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Use only   non-abrasive 
products to clean your spa 

Summary of Contents for sogno dreamwave

Page 1: ......

Page 2: ...K WARNING 10 SAFETY PRECAUTIONS 10 DISPLAY WARNINGS 10 TYPES OF SYMBOLS AND DESCRIPTION 10 SAFETY PRECAUTIONS INSTALLATION 10 SAFETY PRECAUTIONS BEFORE USE 11 SAFETY PRECAUTIONS DURING USE 13 SAFETY P...

Page 3: ...MS 27 CHANGING COURSES 28 MANUAL SELECTION MODE 30 HOW TO OPERATE MANUAL SELECTION MODE 30 BASIC OPERATIONS 30 AIR MASSAGE 31 ROLLING 31 VIBRATION 31 VARIOUS ADJUSTMENTS 32 HOW TO OPERATE MANUAL SELEC...

Page 4: ...Date 24 March 2010 Page 5 of 42 OWNERS MANUAL For Sogno DreamWave Spa IMPORTANT INFORMATION Serial Number Work Order Number Installed by Installation Date The serial number and work order number are...

Page 5: ...H Water Fill Line Capacity 4 5 U S gallons Whirlpool pump motor 110V 1 6 HP 110V 60Hz Seat upholstery Polyurethane Power source 110V 10V AC 2 75 Amps 60 Hz GFCI Protected X Caution Pedicure spa must b...

Page 6: ...5 types Automatic Shiatsu Point Locator Function included in some programs Vibration Massage Function Back 2 levels Min Approx 1650 times minute Max Approx 2350 times minute Seat 1 step Approx 4500 ti...

Page 7: ...us person b Do not use on Insensitive skin Person with poor blood circulation Note Check the skin in contact with the heated area of the appliance frequently to reduce the risk of blistering 4 Excessi...

Page 8: ...but should first consult their physician prior to receiving a pedicure If the client experiences any pain or discomfort discontinue the use of the pedicure spa immediately Your client s massage and pe...

Page 9: ...ypodermis Persons with suspected acute neck sprain whiplash injury Persons with any of the following conditions should seek medical advice before using the chair Serious heart conditions Sensory impai...

Page 10: ...shock Make sure that the plugs on the power cord are inserted fully into the cord connector and the wall outlet May result in electric shock short circuit or combustion Before using the chair for the...

Page 11: ...etween the armrest and the chair Accident personal injury or damage to the chair may result if hands feet or objects are caught Do not use the heater continuously for two hours or longer May result in...

Page 12: ...tage stop the chair immediately and set the main POWER switch to OFF Unplug the chair from the wall outlet Accident or injury may result if the chair is still in operating mode when the power resumes...

Page 13: ...n it Do not remodel the chair Anyone other than an authorized service person must not repair or disassemble Contact the vendor For safety reasons if the power cord is damaged contact the vendor for re...

Page 14: ...o not use any products containing a foaming agent this will cause excessive foam It has been determined that products containing non dissolving abrasives such as sand and sea salts will not harm the i...

Page 15: ...or With state of the art technology Various Course Functions Healthcare programs and Well Being programs that allow you to select the optimal program according to your purpose and Manual Selection mod...

Page 16: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 18 of 42 LOCATION DIMENSIONS CHAIR IS SHOWN IN THE FULLY BACK POSITION AND FULLY RECLINED...

Page 17: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 19 of 42 COMPONENTS DESCRIPTION CHAIR COMPONENTS...

Page 18: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 20 of 42...

Page 19: ...in progress is displayed with both characters and symbols See next page ROLLER Buttons During Preset Programs roller shoulder positions can be adjusted using and immediately after the Shiatsu points a...

Page 20: ...adjusting the roller speed in three steps during Kneading Tapping 1 and Kneading Tapping Width Button For adjusting the width of the rollers in three steps Rolling Button You can select from between F...

Page 21: ...e chair is off the rollers are normally drawn back into the left and right sides of the upper part of the seat back Storage Position For safety reasons first check the positions of the rollers If they...

Page 22: ...s of the Shoulder Massage Unit HOW TO USE THE CHAIR WITHOUT THE SHOULDER MASSAGE UNIT You can have your shoulders massaged by the rollers and not by the Shoulder Massage Unit by securing the Shoulder...

Page 23: ...of the shoulder massage section turn the cover over and then attach the Shiatsu pads at any place where the Velcro is provided according to your preference For easy replacement of the Shiatsu pads rai...

Page 24: ...air is set to ON If the Child Safety Lock is locked operation disabled during operation the heater will turn itself off SPEAKER ON THE REMOTE CONTROL Button Indication The sound from the speaker can b...

Page 25: ...arch 2010 Page 27 of 42 PRESET PROGRAMS Eight automatic programs provide a variety of different massages to relieve fatigue With the Preset Program buttons you can choose your favorite program which w...

Page 26: ...tensity of air massage is reset to its initial setting MED Back Vibe Button The intensity of a back vibration operation can be adjusted with the Back Vibe button located behind the panel of the remote...

Page 27: ...int Locator starts locating Shiatsu points The Automatic Shiatsu Point Locator is not available during Full Body Air Program and DreamWave Program Note For accurate Shiatsu Point location always sit a...

Page 28: ...ation is selected Operation Button Action Indication Forward Reverse Speed Width Up Down Intensity Kneading This performs kneading type of massage Each time the button is pressed forward direction rev...

Page 29: ...rogram Operation Button Action Indication Width Up Down Full Rolling Rolling This performs stretching of the full or partial spine with only up and down movements of the rollers Each time the button i...

Page 30: ...ring Partial Rolling the center position of the range of Partial Rolling can be adjusted If or is pressed during Full Rolling upward or downward movement is reversed SPEED BUTTONS Operation Button Ind...

Page 31: ...n the power to the remote control is shut off However reclining of the seat back and ON OFF of the heater are still enabled CHANGING COURSES SWITCHING FROM MANUAL SELECTION MODE TO A PRESET PROGRAM Wh...

Page 32: ...performing the procedures provided in subsection b 1 through 6 and after the last client each pipe free pedicure spa shall be cleaned and disinfected in the following sequential manner 1 Fill the basi...

Page 33: ...RING FOR OTHER PLASTIC PARTS Soak a piece of soft cloth in lukewarm water in which a small amount of mild detergent has been added thoroughly wring it out and clean off any spots or grime Then wipe wi...

Page 34: ...0 Bulkhead Fitting 2 64 25022014 Escutcheon 1 22 06130087 Washer 7 8 Red 1 65 30040200 Motor 1 23 06130088 Washer 7 8 Blue 1 66 12130035 Screw 1 4 20x1 2 16 24 15130016 Check Valve 4 67 12130048 Nut 1...

Page 35: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 37 of 42...

Page 36: ...Verify motor is plugged in to gray control box 3 Verify fuse in the gray control box is in tact 4 Verify the wires to the button are not cut 5 Remove clean touch assembly and verify the impeller is i...

Page 37: ...if the power cord is fully plugged into the wall outlet 6 Check if the power cord is fully plugged into the power connector located at the rear of the chair 7 Check if the main POWER switch at the rea...

Page 38: ...ere with your movements when getting out of the chair To continue massaging press the POWER button on the remote control again THE RIGHT AND LEFT ROLLERS ARE OUT OF ALIGNMENT The rollers are designed...

Page 39: ...e the intensity by removing the buffer pad located at the rear of the back pad HOW DO I MAKE THE MASSAGE LIGHTER During Preset Programs adjust the intensity of massage with the BACK 3 D AIR LEVEL Back...

Reviews: