Instruction Manual MIXPRO 28 EUROPRO pag.25
ROUTINE MAINTENANCE
The operations of routine maintence must be done only by competent and
experienced staff.
The replacement of the machine components must be carried out only with
original spare parts.
FREQUENCY
AREA
INTERVENTION
Every 10-15 hours
of work
Rotor (screw) stator
(plenum chamber) used
with cement products.
Replacement
Every 30-40 hours
of work
Rotor (screw) stator
(plenum chamber) used
with gaseous products.
Replacement
Every 100-150
hours of work
Mixer
Replacement
Daily
Safety devices
Functional verification
Material conveying tube,
air tube and power
supply cable.
Visual inspection of tear
status.
Weekly
Gearmotor.
Visual inspection and, if
necessary, topping up with
oil type BERGOIL
“BERGOFLUID 1000” or
equivalent.
Water filter.
Cleaning
Compressor filter.
Cleaning
Six-monthly
Compressor filters.
Replacement
Gaskets of chamber mixing
(Camix).
Replacement