background image

1

Modular Push Bar Panic Bolt with Vertical Rods Rev.7

Installation Instructions

Modular Push Bar Panic Bolt with Vertical Rods to EN1125

IMPORTANT INFORMATION

PLEASE READ THESE INSTRUCTIONS CAREFULLY

This product is non handed and can be fitted on both left handed and right handed doors. 

For internal use only.

Door – Maximum specification of door on which this product should be fitted.

Maximum weight of door = 200kg

• Maximum height of door = 2500mm

• Maximum width of door = 1300mm (1170mm Bar) – 1100mm (730mm Bar)

This product is designed for peoples safety and complies with EN 1125. 

Do not

modify 

the product in anyway other than those outlined in these instructions.

Summary of Contents for Push Bar Panic Bolt

Page 1: ...and can be fitted on both left handed and right handed doors For internal use only Door Maximum specification of door on which this product should be fitted Maximum weight of door 200kg Maximum heigh...

Page 2: ...n X 1 6 Top Keep X 1 7 Top Tripper Guide X 1 8 Plain Guides X 3 9 Bottom Keep X 1 10 Plastic End Caps X 2 11 Shoot Bolts X 2 PARTS LIST 12 Knurled Plugs X 2 13 Allen Key X 1 14 ES Logo Labels X 2 15 S...

Page 3: ...eel or aluminium Doors Door size limitations Maximum clear opening height 2450mm Minimum clear opening width 400mm per door Single Door Rebated Double Door Non Rebated Double Door Door shown with Modu...

Page 4: ...level Fig 4 3 6 Cut tubular rods Items 2 3 to the lengths measured less 88mm for both See Fig 4 3 Note Both rods have pre drilled holes for fitting to the Rod connectors Items 18 therefore ensure the...

Page 5: ...in guide Item 8 onto the top rod Item 3 then screw the shoot bolt Item 11 fully into the knurled plug Item 12 Slip the two remaining plain guides Items 8 over the bottom rod Item 2 then screw the rema...

Page 6: ...uide Item 7 over the top shoot bolt and close the door Fully depress the push bar lever inset 3mm packer to hold the top shoot bolt This now gives the position of the top guide Mark through and secure...

Page 7: ...Bolt Box If the door is too narrow remember to leave a 10mm gap between end box and door frame Mark through and secure into position 14 Place End Box blanking cover item 22 onto bottom of metal base d...

Page 8: ...rectly and periodically apply grease to top and bottom shoot bolts PLEASE LEAVE THESE INSTRUCTIONS WITH THE END USER Stancliffe Street Mill Hill Blackburn BB2 2QR Tel 44 0 1254 274100 Fax 44 0 1254 27...