- 13 -
GB
2.1
INFORMATION ABOUT GAS HEATED GRIDDLE PLATES
This manual applies to our Gas Heated Griddle Plates Type A1 Category II (Natural Gas and L.P.G.).
See table 1.1 and 2.6
The label according to EN437 and EN203 regulations, Part 1, is located inside the unit and/or at back.
Example for Italy label: Category II 2H3+
Pe = Incoming Pressure
Pi = Nozzle Pressure
2.2
LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE COMPLIED WITH
The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the gas supply Company, which should issue an authorisation before installation
- Instructions for the “Installation of gas equipment”
- Hygienic regulations.
2.3
INSTALLATION PLACE
- The unit should be installed in adequately ventilated places. This unit requires a draft of at least 2cu.m/hr l kW T.C.
(Thermal Capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed.
2.4
POSITIONING
- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.
2.5
MOUNTING THE TOP UNITS ON A BASE OR AN EXTENDING SUPPORT
All Top units are supplied with height-adjustable feet (P):
- When the unit is to be placed free on a table or a surface,
tighten or loosen the feet (P) as shown in the illustration
till it is perfectly steady, then tighten the locknut (D) so
that the foot is blocked. To prevent slipping, insert the
rubber plugs (M) into the feet’s lower holes.
- When the unit is to be fixed to a base or an extending
support, adjust the feet (P) till it is perfectly steady, then
tighten the locknut (D) so that the foot is blocked.
Subsequently fasten from beneath by way of M5 screws
(T) and respective washers, screwing them into the feet
as shown in the illustration.
V
Hz
kW
Type
tipo
Mod.
Matr.N°
Cat.
P n
Cat.
P n
PT
Qn
(Hi)
G20
G25
m
3
/h
m
3
/h
G30
G31
Kg/h
Kg/h
mbar
KW
mbar
II2H3B/P
20,50/50
II2L3B/P
25,30,30
NL
AT-CH
II2H3B/P
20,30/30
II2H3+
PL
IS-MT-CY
FR - BE
DE
LU
IT-GR-GB-ES-IE-PT
II2H3+
20,29/37
II2E+3+
20/25,29/37
II2ELL3B/P
20,20,50/50
I3B/P
30/30
II2E3P
20/37
I2E; I3+
20,29/37
20,50/67
NO-SE-EE-LT-DK-LV-CZ-SK-SI-FI-TR-HR-BG-RO