Advanced Configuration
VoIP²ALL 8 - 16 - 24 Channel Gateway User Guide
www.eurotech-communication.com
22
To define a Time Table:
1)
From the Main Toolbar, click
Ports
.
2)
In the ports list on the left side of the window, select
General
.
3)
In Default SIM, select
Local SIM work by time table.
4)
On the left side of the window, select a port from the ports list.
5)
From the
Available SIMs
list, select
L1
(Local 1).
6)
In
Type
, select the type of schedule you want to define from the following options:
Monthly
- The table will show all the days of the month.
Weekly
- The table will show all the days of the week.
7)
In
Swapping Type
, select one of the following options:
Time Table
- The SIM is replaced at the end of its defined time in the Time Table. In this mode
you set up a Time Table and define which SIM will work in which hour.
Call Duration
- The SIMs are replaced when they end their defined calling minutes. In this
mode you define a list of SIMs in the table. For each SIM in the list you define the amount of
calling units to be used. Each SIM will work for the defined calling minutes and then be
replaced with the next SIM on the list.
Manual
- This gives you the option of manually connecting a SIM immediately. This is
recommended for temporary use only, generally by support in the debug process.
8)
In the Time Table, define the hour and day for the Local SIM to register.
In the time slot you can see the information of the SIM in this format: L1
9)
Click
Save
.
10)
Insert the SIMs to the cellular ports Local SIM sockets.
11)
At the defined time, the Local SIM will register in the cellular network.
4.1.3.
ASSIGNING A LOCAL SIM TO WORK FOR A LIMITED CALLING TIME
In the Call Duration mode, each SIM works for a defined number of call minutes.
At the beginning of the day, the Gateway registers a SIM from the list and then counts down the
number of units defined for that SIM until it reaches 0.
The Gateway then registers the next SIM from the list. This process continues until all of the SIMs on
the list have finished their defined time units.
The Gateway resets the time unit count to the original definitions at the beginning of every month or
week, depending on the
Type
selected in the
Time Table
.
The calculation of the units per interval
The Gateway calculates the call duration by intervals. An interval is a minimum billing duration.
When making a call shorter than 1 interval, you will be charged the entire interval cost.