Find the best mounting location
PCN-1001 User manual
24
PCN-1001_UserMan_En_4.0
The PCN-1001 field of view and the Detection area
The PCN’s field of view
The two PCN-1001 stereoscopic cameras have a specific field of view:
•
The viewing angle relative to the long side of the front panel is about 70 degrees
•
The viewing angle relative to the short side is about 55 degrees
The field of view can be seen as a pyramid with a rectangular base. The dimensions of the base will change
according to the PCN-1001 installation height and follow these formulas:
D = 2H tan(55/2) = 2H * 0.52
W = 2H tan(70/2) = 2H * 0.70
EXAMPLE:
If H = 225 cm then D = 234 cm and W = 315 cm