17
601-000147 Rev. Y
Arch. 5105
25/02/2016
In order to simplify the explanation of how to set all the parameters for a proper operation, it is
useful to separate Indoor version and Outdoor version set-up instructions.
Indoor version
An Indoor version is basically composed by:
EK-MFR/2
EK-UCM/x (where '/x' = band of the Up Converter, e.g. UCM/10 = Up Converter in 10 GHz
Band, see 'EK-UCM/X' User's Handbook).
EK-AMP/x (where „/x‟=band of the Amplifier, see 'EK-AMP/x' User's Handbook), is an
option.
EK-UNM/x (where „/x‟=version of the Modem, see 'EK-UNM/x' User's Handbook).
There are several software revisions of UCM/x which require different set-up, and these are shown in
the table below.
The power loop has to be activated only if an amplifier is used.
The EK-UNM/x output can be set to the desired modality (Mod/IF2/CW) and “IF Tx Level Set” has
to be set in the range [-10dBm ÷ 0 dBm].
(*) The model of the modem can be EK-UNM/2 or EK-UNM/3