33
601-000147 Rev. Y
Arch. 5105
25/02/2016
>>Day
>>Hour
>>Minute
It is not available the automatic setting of the
summer time
.
>Network
The Network menu allows to set, using the “modifying variable” keys, the following network
configuration parameters, for the system:
>> IP mode (static or DHCP).
Static =
The user set the IP Address.
DHCP = The EK-MFR/2 is a DHCP Client and get the IP Addres from a DHCP server
automatically.
>> IP address.
>> IP netmask.
>> GW address
.
When the network configuration are changed by the user, the EK-MFR/2 must be rebooted.
5.3 T
EMPERATURE CONTROL
The EK-MFR/2 allows a reliable control of the temperature. To minimize the use and the
maintenance of the two fans, EK-MFR/2 controls the rate of the same fans. The highest temperature
registered on the inserted boards is used to control the fans. The monitoring of the board temperature
can be done in the sub-menus and the memorization and settling of the limits can generate possible
alarms.
6. L
EDS AND
A
LARMS
6.1 L
ED DESCRIPTION
On (green light) : indicates that the EK-MFR/2 is active. The light is always on also if the
display and the keys are off (if the user has to set the time to exit in the
Miscellaneous
menu
of the EK-MFR/2).
Actual (red light) : indicates that an alarm is present, a variable of any of the boards does not
respect the limit. The light turns off when the variable returns inside the limit.
Stored (yellow light) : indicates that an alarm is present, the light turns off when any of the
keys is pushed.
The LEDs position is reported in the
front panel
chapter.
Summary of Contents for EK-MFR/2
Page 1: ...1 601 000147 Rev Y Arch 5105 25 02 2016 User Manual System ALL4DIGIT EK MFR 2 ...
Page 9: ...9 601 000147 Rev Y Arch 5105 25 02 2016 1 1 EK MFR 2 BLOCK SCHEME ...
Page 18: ...18 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y Tabella 5 1 Indoor version Set up Table ...
Page 66: ...66 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y ...