43
601-000147 Rev. Y
Arch. 5105
25/02/2016
APPENDIX
D
SNMP
–
V
IRTUAL SLOT
The EK-MFR/2 snmp-server default operation mode uses "Octect String" data types. In this mode
you can set and get any variable using SNMP string types.
In order to use integer types too, you have to point to a "virtual slot" (named "NEW OID" in the
configuration file) that maps new, virtual oid into the real oid.
The virtual slot mode allows you to use more than the integer types; the new functions implemented
with this system are:
- get/set variables using octect string type;
- get/set variables using integer type;
- get/set variables in "boolean" mode;
- scale factor for float/integer conversion;
- offset factor for "get" operations;
- traps generation;
These features are described in a configuration file. The name of this file is divided in 2 part: the first
part must be fix (SnmpVirtualSlotDataBase), the second part is arbitrary. For example a possible
name is “SnmpVirtualSlotDataBase_prova”.
An example of configuration file is reported in figure 1.
Every line is composed with the fields reported in table 1.
Notes about the configuration file syntax:
Lines starting with a # are notes and are not used for the virtual slot data base construction;
Every field must be enclosed in squared brackets;
Octect string MUST be written as read in the RemoteMenu field.
Summary of Contents for EK-MFR/2
Page 1: ...1 601 000147 Rev Y Arch 5105 25 02 2016 User Manual System ALL4DIGIT EK MFR 2 ...
Page 9: ...9 601 000147 Rev Y Arch 5105 25 02 2016 1 1 EK MFR 2 BLOCK SCHEME ...
Page 18: ...18 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y Tabella 5 1 Indoor version Set up Table ...
Page 66: ...66 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y ...