FILLING
PREPARATION OF MIXTURE OF WATER + glycol
Glycol is supplied separately in the standard package and mixed with water in the tank before filling the
installations (for example. 40% glycol and 60% water-resistant to frost temperatures from -21 ° C).
Fill the solar system exclusively with polypropylene glycol which is intended specifically for use in solar
devices. Polypropylene glycol retains its properties in the area of 32 ÷ 180 ° C.
Polypropylene glycol is biologically compatible and not toxic.
Do not fill pure glycol first and then add water.
If the water contains a high level of chlorine is it necessary to use a distilled water .
Antifreeze temperature Density
50% -32 ° C
1.045 kg/dm3
40% -21 ° C
1037 kg/dm3
30% -13 ° C
1.029 kg/dm2
FILLING
1 - Open the valve (A)
2 - The manual venting valve at the highest point (see
drawing ) shall be open during charging
3 - Open the venting valve (7)
4 - Allow the liquid driven by external pump circulates until all air
bladders are removed. Close the manual venting valve.
5 - Raise the pressure in the installation at 4 bar.
6 - Leave the installation to work about 20 minutes
7 - Repeat the procedure from point 2, while
the air is completely dropped
8 - Adjust the pressure in the installation of 3 bar.
- Close the valve (A) and venting valves, to prevent possible
evaporation of heat transfer fluid.
Do not fill the installation during full insolation and while collectors are hot.
The system must not be replenished with water.
7
A
Summary of Contents for ESK 2.5 SB
Page 2: ......
Page 4: ......
Page 18: ...FACADE MOUNTING rain protection profile use four antislip protection bracket ...