CONNECTABLE PARTS (SOL VERSION)
The specific components of the solar system controllable by
the unit's controller are:
B
= solar circuit pump
C
= excess heat dissipating valve *
H
= collector temperature sensor
*
: this consent is activated when a critical temperature read by
the probe placed in the hottest part of the panel is exceeded .
This signal can be used in different ways, such as opening a
radiance control shutter, opening a valve in a heat dissipation
system or opening a system discharge valve .
The value at which this consent is activated is among the
parameters settable by the installer .
The characteristics of the connections are given in the table .
INSTALLATION
Fig .4
Fig .5
The temperature sensor to be placed in the hottest part of the solar collector is supplied .
Data
Connection
U .M
Terminals
6-7
8-9
10-11
Type
Output
Output
Input NTC
Voltage
230-1-50
230-1-50
\
V-ph-Hz
Max . current
5
2
\
A
Characteristics
\
\
50kΩ/25°C
type