$SSHQGLFHV
##
<05:
953#
9HFWRU
#
'ULYH
#0#
+$
7968;7
Tag
Mn
Text
Default EIASCII
Enum
Min
Max
CFG
RO
649
i1
::SETUP PARAMETERS::REF ENCODER::PHASE::TEST MODE::SPEED SETPOINT 2
10.00%
10
-100
100
RECFG
RW
607
gv
::SETUP PARAMETERS::REF ENCODER::REF.SPEED
356
9w
::SETUP PARAMETERS::REF ENCODER::REF.SPEED::ENCODER LINES
2048
2048
0
8000
RECFG
RW
767
lb
::SETUP PARAMETERS::REF ENCODER::REF.SPEED::FILTER TC
1.00 SECS
1
0
300
RECFG
RW
768
lc
::SETUP PARAMETERS::REF ENCODER::REF.SPEED::FILTERED REF.SPD
0.00%
0
-300
300
RECFG
RO
353
9t
::SETUP PARAMETERS::REF ENCODER::REF.SPEED::MAX SPEED RPM
1500 RPM
1500
0
6000
RECFG
RW
357
9x
::SETUP PARAMETERS::REF ENCODER::REF.SPEED::REFSPEED
0.00%
0
-300
300
RECFG
RW
783
lr
::SETUP PARAMETERS::REF ENCODER::REF.SPEED::SCALE REF.SPEED
TRUE
>0001
FALSE; TRUE;
0
1
RECFG
RW
188
58
::SETUP PARAMETERS::SETPOINT SUM 1
193
5d
::SETUP PARAMETERS::SETPOINT SUM 1::DIVIDER 0
1
1
-3
3
RECFG
RW
194
5e
::SETUP PARAMETERS::SETPOINT SUM 1::DIVIDER 1
1
1
-3
3
RECFG
RW
196
5g
::SETUP PARAMETERS::SETPOINT SUM 1::INPUT 0
0.00%
0
-100
100
RECFG
RW
197
5h
::SETUP PARAMETERS::SETPOINT SUM 1::INPUT 1
0.00%
0
-100
100
RECFG
RW
198
5i
::SETUP PARAMETERS::SETPOINT SUM 1::INPUT 2
0.00%
0
-100
100
RECFG
RW
195
5f
::SETUP PARAMETERS::SETPOINT SUM 1::LIMIT
100.00%
100
0
300
RECFG
RW
189
59
::SETUP PARAMETERS::SETPOINT SUM 1::RATIO 0
1
1
-3
3
RECFG
RW
190
5a
::SETUP PARAMETERS::SETPOINT SUM 1::RATIO 1
1
1
-3
3
RECFG
RW
191
5b
::SETUP PARAMETERS::SETPOINT SUM 1::SIGN 0
POS
>0001
NEG; POS;
0
1
RECFG
RW
192
5c
::SETUP PARAMETERS::SETPOINT SUM 1::SIGN 1
POS
>0001
NEG; POS;
0
1
RECFG
RW
46
1a
::SETUP PARAMETERS::SETPOINT SUM 1::SPT SUM O/P 1
0.00%
0
-100
100
NOCFG
RO
363
a3
::SETUP PARAMETERS::SETPOINT SUM 2
368
a8
::SETUP PARAMETERS::SETPOINT SUM 2::DIVIDER 0
1
1
-3
3
RECFG
RW
369
a9
::SETUP PARAMETERS::SETPOINT SUM 2::DIVIDER 1
1
1
-3
3
RECFG
RW
371
ab
::SETUP PARAMETERS::SETPOINT SUM 2::INPUT 0
0.00%
0
-100
100
RECFG
RW
372
ac
::SETUP PARAMETERS::SETPOINT SUM 2::INPUT 1
0.00%
0
-100
100
RECFG
RW
373
ad
::SETUP PARAMETERS::SETPOINT SUM 2::INPUT 2
0.00%
0
-100
100
RECFG
RW
370
aa
::SETUP PARAMETERS::SETPOINT SUM 2::LIMIT
100.00%
100
0
300
RECFG
RW
364
a4
::SETUP PARAMETERS::SETPOINT SUM 2::RATIO 0
1
1
-3
3
RECFG
RW
365
a5
::SETUP PARAMETERS::SETPOINT SUM 2::RATIO 1
1
1
-3
3
RECFG
RW
366
a6
::SETUP PARAMETERS::SETPOINT SUM 2::SIGN 0
POS
>0001
NEG; POS;
0
1
RECFG
RW
367
a7
::SETUP PARAMETERS::SETPOINT SUM 2::SIGN 1
POS
>0001
NEG; POS;
0
1
RECFG
RW
385
ap
::SETUP PARAMETERS::SETPOINT SUM 2::SPT SUM O/P 2
0.00%
0
-300
300
NOCFG
RO
374
ae
::SETUP PARAMETERS::SETPOINT SUM 3
379
aj
::SETUP PARAMETERS::SETPOINT SUM 3::DIVIDER 0
1
1
-3
3
RECFG
RW
380
ak
::SETUP PARAMETERS::SETPOINT SUM 3::DIVIDER 1
1
1
-3
3
RECFG
RW
382
am
::SETUP PARAMETERS::SETPOINT SUM 3::INPUT 0
0.00%
0
-100
100
RECFG
RW
383
an
::SETUP PARAMETERS::SETPOINT SUM 3::INPUT 1
0.00%
0
-100
100
RECFG
RW
384
ao
::SETUP PARAMETERS::SETPOINT SUM 3::INPUT 2
0.00%
0
-100
100
RECFG
RW
381
al
::SETUP PARAMETERS::SETPOINT SUM 3::LIMIT
100.00%
100
0
300
RECFG
RW
375
af
::SETUP PARAMETERS::SETPOINT SUM 3::RATIO 0
1
1
-3
3
RECFG
RW
376
ag
::SETUP PARAMETERS::SETPOINT SUM 3::RATIO 1
1
1
-3
3
RECFG
RW
377
ah
::SETUP PARAMETERS::SETPOINT SUM 3::SIGN 0
POS
>0001
NEG; POS;
0
1
RECFG
RW
378
ai
::SETUP PARAMETERS::SETPOINT SUM 3::SIGN 1
POS
>0001
NEG; POS;
0
1
RECFG
RW
386
aq
::SETUP PARAMETERS::SETPOINT SUM 3::SPT SUM O/P 3
0.00%
0
-300
300
NOCFG
RO
160
4g
::SETUP PARAMETERS::SPEED LOOP
779
ln
::SETUP PARAMETERS::SPEED LOOP::ADVANCED
149
45
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::1 / GAIN
70
70
0
255
RECFG
RI
675
ir
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::ADAPTIVE P-GAIN
10
10
0
250
RECFG
RW
674
iq
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::ADAPTIVE THRESH
0.00%
0
0
10
RECFG
RW
638
hq
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL
644
hw
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL::ACCEL RATE
0.50%
0.5
0
300
RECFG
RW
657
i9
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL::CONTROL
BAND
20 VOLTS
20
0
1000
RECFG
RW
641
ht
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL::DECEL RATE
2.50%
2.5
-100
100
RECFG
RW
639
hr
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL::ENABLEFALSE
>0000
FALSE; TRUE;
0
1
RECFG
RW
766
la
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL::PWR LOSS
ACTIVE
FALSE
>0000
FALSE; TRUE;
0
1
RECFG
RO
643
hv
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL::TIME LIMIT
30.000 SECS
30
0
30
RECFG
RW
640
hs
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::PWR LOSS CNTRL::TRIP
THRESHOLD
0 VOLTS
0
0
1000
RECFG
RW
769
ld
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::ROTOR TEMP
100.00%
100
0
100
RECFG
RW
662
ie
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::SPEED DMD FILTER
0.75
>02EE
0
1
NOCFG
RW
673
ip
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::SPEED FBK FILTER
0.5
>01F4
0
1
NOCFG
RW
784
ls
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::Tr COMP
0.00%
0
0
100
NOCFG
RO
770
le
::SETUP PARAMETERS::SPEED LOOP::ADVANCED::Tr COMP (COLD)
80.00%
80
50
100
RECFG
RW
51
1f
::SETUP PARAMETERS::SPEED LOOP::ENCODER
0 RPM
0
-20000
20000
NOCFG
RO
163
4j
::SETUP PARAMETERS::SPEED LOOP::INT. DEFEAT
FALSE
>0000
FALSE; TRUE;
0
1
RECFG
RW
8
8
::SETUP PARAMETERS::SPEED LOOP::SPEED ERROR
0.00%
0
-300
300
NOCFG
RO
7
7
::SETUP PARAMETERS::SPEED LOOP::SPEED FB UNFIL
0.00%
0
-300
300
NOCFG
RO
11
0b
::SETUP PARAMETERS::SPEED LOOP::SPEED FEEDBACK
0.00%
0
-300
300
NOCFG
RO