<05;##
$SSHQGLFHV
953#
9HFWRU
#
'ULYH
#0#
+$
7968;7
Tag
Mn
Text
Default EIASCII
Enum
Min
Max
CFG
RO
48
1c
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINT
0.00%
0
-300
300
NOCFG
RO
170
4q
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS
175
4v
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::DIRECT ENABLE
FALSE
>0000
FALSE; TRUE;
0
1
RECFG
RW
172
4s
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::DIRECT RATIO
0.1
0.1
-1
1
RECFG
RW
173
4t
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::DIRECT SPT. MAX
100.00%
100
0
100
RECFG
RW
174
4u
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::DIRECT SPT. MIN
-100.00%
-100
-100
0
RECFG
RW
171
4r
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::DIRECT SPT1
0.00%
0
-300
300
NOCFG
RO
176
4w
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::MAIN SPD.SPT.
0.00%
0
-110
110
RECFG
RW
177
4x
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::MAX SPEED
100.00%
100
0
110
RECFG
RW
178
4y
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::MIN SPEED
-100.00%
-100
-110
0
RECFG
RW
50
1e
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::SEQ OUTPUT
0.00%
0
-100
100
NOCFG
RO
49
1d
::SETUP PARAMETERS::SPEED LOOP::SPEED SETPOINTS::SEQ RUN INPUT
0.00%
0
-100
100
NOCFG
RO
6
6
::SETUP PARAMETERS::SPEED LOOP::TOTAL SPD.DMD.
0.00%
0
-300
300
NOCFG
RO
778
lm
::SETUP PARAMETERS::SPEED LOOP::ZERO SPEED
19
0j
::SETUP PARAMETERS::SPEED LOOP::ZERO SPEED::AT STANDSTILL
FALSE
>0000
FALSE; TRUE;
0
1
NOCFG
RO
18
0i
::SETUP PARAMETERS::SPEED LOOP::ZERO SPEED::AT ZERO SETPOINT
FALSE
>0000
FALSE; TRUE;
0
1
NOCFG
RO
17
0h
::SETUP PARAMETERS::SPEED LOOP::ZERO SPEED::AT ZERO SPEED
FALSE
>0000
FALSE; TRUE;
0
1
NOCFG
RO
132
3o
::SETUP PARAMETERS::SPEED LOOP::ZERO SPEED::ZERO SPD HYST
0.10%
0.1
0
100
RECFG
RW
252
70
::SETUP PARAMETERS::SPEED LOOP::ZERO SPEED::ZERO SPEED LEVEL
0.50%
0.5
0
100
RECFG
RW
317
8t
::SETUP PARAMETERS::S-RAMP
253
71
::SETUP PARAMETERS::S-RAMP::ACCEL O/P
0
0
-300
300
NOCFG
RO
106
2y
::SETUP PARAMETERS::S-RAMP::ACCELERATION
10
10
0
150
RECFG
RW
316
8s
::SETUP PARAMETERS::S-RAMP::AT SPEED
FALSE
>0000
FALSE; TRUE;
0
1
NOCFG
RO
612
h0
::SETUP PARAMETERS::S-RAMP::AT SPEED LEVEL
1.00%
1
0
100
RECFG
RW
669
il
::SETUP PARAMETERS::S-RAMP::AUTO RESET
TRUE
>0001
FALSE; TRUE;
0
1
RECFG
RW
666
ii
::SETUP PARAMETERS::S-RAMP::DECELERATION
10
10
0
150
RECFG
RW
668
ik
::SETUP PARAMETERS::S-RAMP::ERROR THRESHOLD
0.50%
0.5
0
100
RECFG
RW
104
2w
::SETUP PARAMETERS::S-RAMP::EXTERNAL RESET
FALSE
>0000
FALSE; TRUE;
0
1
RECFG
RW
597
gl
::SETUP PARAMETERS::S-RAMP::INPUT
0.00%
0
-100
100
RECFG
RW
107
2z
::SETUP PARAMETERS::S-RAMP::JERK 1
10
10
0
150
RECFG
RW
663
if
::SETUP PARAMETERS::S-RAMP::JERK 2
10
10
0
150
RECFG
RW
664
ig
::SETUP PARAMETERS::S-RAMP::JERK 3
10
10
0
150
RECFG
RW
665
ih
::SETUP PARAMETERS::S-RAMP::JERK 4
10
10
0
150
RECFG
RW
598
gm
::SETUP PARAMETERS::S-RAMP::OUTPUT
0.00%
0
-100
100
NOCFG
RO
254
72
::SETUP PARAMETERS::S-RAMP::OVERSHOOT THRESH
5.00%
5
0
100
RECFG
RW
108
30
::SETUP PARAMETERS::S-RAMP::QUENCH
FALSE
>0000
FALSE; TRUE;
0
1
RECFG
RW
105
2x
::SETUP PARAMETERS::S-RAMP::RESET VALUE
0.00%
0
-100
100
RECFG
RW
667
ij
::SETUP PARAMETERS::S-RAMP::SYMMETRIC
TRUE
>0001
FALSE; TRUE;
0
1
RECFG
RW
119
3b
::SETUP PARAMETERS::STOP RATES
26
0q
::SETUP PARAMETERS::STOP RATES::COAST STOP
FALSE
>0000
FALSE; TRUE;
0
1
NOCFG
RO
112
34
::SETUP PARAMETERS::STOP RATES::CONTACTOR DELAY
0.5 SECS
0.5
0
1000
RECFG
RW
124
3g
::SETUP PARAMETERS::STOP RATES::FAST STOP LIMIT
60.0 SECS
60
0
1000
RECFG
RW
123
3f
::SETUP PARAMETERS::STOP RATES::FAST STOP TIME
1.0 SECS
1
0
1000
RECFG
RW
777
ll
::SETUP PARAMETERS::STOP RATES::PILOT 590 MODE
FALSE
>0000
FALSE; TRUE;
0
1
RECFG
RW
122
3e
::SETUP PARAMETERS::STOP RATES::PRE-START DELAY
0.500 SECS
0.5
0
30
RECFG
RW
622
ha
::SETUP PARAMETERS::STOP RATES::PROG STOP I-LIM
150.00%
150
0
200
RECFG
RW
22
0m
::SETUP PARAMETERS::STOP RATES::PROGRAM STOP
FALSE
>0000
FALSE; TRUE;
0
1
NOCFG
RO
352
9s
::SETUP PARAMETERS::STOP RATES::READY DELAY
0.000 SECS
0
0
30
RECFG
RW
121
3d
::SETUP PARAMETERS::STOP RATES::RUN STOP LIMIT
60.0 SECS
60
0
1000
RECFG
RW
120
3c
::SETUP PARAMETERS::STOP RATES::RUN STOP TIME
10.0 SECS
10
0
1000
RECFG
RW
126
3i
::SETUP PARAMETERS::STOP RATES::STOP ZERO SPEED
1.00%
1
0
100
RECFG
RW
125
3h
::SETUP PARAMETERS::STOP RATES::USE SYSTEM RAMP
TRUE
>0001
FALSE; TRUE;
0
1
RECFG
RW
147
43
::SETUP PARAMETERS::TORQUE LOOP
599
gn
::SETUP PARAMETERS::TORQUE LOOP::AUX TORQUE DMD
0.00%
0
-200
200
RECFG
RW
78
26
::SETUP PARAMETERS::TORQUE LOOP::CURRENT FEEDBACK
0.00%
0
-300
300
NOCFG
RO
613
h1
::SETUP PARAMETERS::TORQUE LOOP::DC LINK VOLTS
0 VOLTS
0
-30000
30000
NOCFG
RO
684
j0
::SETUP PARAMETERS::TORQUE LOOP::DC VOLTS UNFLT
0 VOLTS
0
-30000
30000
NOCFG
RO
480
dc
::SETUP PARAMETERS::TORQUE LOOP::TERMINAL VOLTS
0 VOLTS
0
-10000
10000
NOCFG
RO
596
gk
::SETUP PARAMETERS::TORQUE LOOP::TORQ.DMD.ISOLATE
FALSE
>0000
FALSE; TRUE;
0
1
RECFG
RW
9
9
::SETUP PARAMETERS::TORQUE LOOP::TORQUE DEMAND
0.00%
0
-300
300
NOCFG
RO
10
0a
::SETUP PARAMETERS::TORQUE LOOP::TORQUE FEEDBACK
0.00%
0
-300
300
NOCFG
RO
780
lo
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS
14
0e
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS::ACTUAL NEG I LIM0.00%
0
-300
300
NOCFG
RO
13
0d
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS::ACTUAL POS I LIM0.00%
0
-300
300
NOCFG
RO
16
0g
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS::AT CURRENT LIMIT
FALSE
>0000
FALSE; TRUE;
0
1
NOCFG
RO
585
g9
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS::CURRENT LIMIT 150.00%
150
50
150
RECFG
RW
158
4e
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS::NEG TORQUE LIMIT
-150.00%
-150
-200
200
RECFG
RW
157
4d
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS::POS TORQUE LIMIT
150.00%
150
-200
200
RECFG
RW
153
49
::SETUP PARAMETERS::TORQUE LOOP::TORQUE LIMITS::SYMMETRIC TQ.LIM.
TRUE
>0001
FALSE; TRUE;
0
1
RECFG
RW
242
6q
::SYSTEM
244
6s
::SYSTEM::CONFIGURE I/O
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com