3200 Series
84 Part No HA028651 Issue 7.0 Apr-09
Parameter
Mnemonic
Parameter Name
Modbus Address
Decimal
1 – Mins:Secs
SS.SP
Soft Start Setpoint
322
SS.PWR
Soft Start Power Limit
323
DWELL
Requested Timer Duration
324
T.ELAP Elapsed
Time
325
T.REMN Time
Remaining
326
THRES
Timer Start threshold
327
End.T
Timer End Type
0 – Off
1 – Dwell at current setpoint
2- Transfer to Setpoint 2 and dwell
3 – Reset programmer when the program ends
328
SERVO
‘Servo’ Mode (programmer option only)
0 – Start first ramp from current Working Setpoint. Program must be restarted after power failure
1 - Start first ramp from current PV (temperature). Program must be restarted after power failure
2 - Start first ramp from current Working Setpoint. Program will continue to run after power failure
3 - Start first ramp from current PV (temperature). Program must be restarted after power failure
329
EVENT Event
outputs
331
P.CYCL
Number of program cycles
332
CYCLE
Currently running program cycle
333
CTRL.H
Heat/Ch1 Control Type
0 – Off
1 – On/Off Control
2 – PID Control
3 – mtr Valve Position Control
512
CTRL.C
Cool/Ch2 Control Type
0 – Off
1 – On/Off Control
2 – PID Control
513
PB.UNT
Proportional Band Units
0 – Engineering Units
1 – Percent of Span
514
Lev2.P
Level 2 Code
515
UNITS
Display Units
0 – Degrees C
1 – Degrees F
2 – Kelvin
3 – None
4 – Percent
516
Lev3.P
Level 3 Code
517
Conf.P Config
Code
518
Cold
If set to 1 instrument will reset to factory defaults on next reset or power cycle.
519
PASS.C
Feature passcode C
520
PASS.2
Feature passcode 2
521
COOL.t Cooling
Algorithm Type:
0 – Linear
1 – Oil
2 – Water
3 – Fan
524
DEC.P
Decimal Point Position
0 – XXXX.
1 – XXX.X
2 – XX.XX
525
STBY.T
Standby Type
0 – Absolute Alarm Outputs Active – others off
1 – All outputs inactive
530
RAMP
0 – Ramp per Minute
531