Part number HA028582. Issue 6.0 May-07 47
5.7
Soft Start Timer
‘
TI.CFG’ = ‘SS.St’.
A Soft Start timer starts
automatically on power up. It applies a power limit
(‘
SS.PWR’)
until the temperature reaches a
threshold value (‘
SS.SP’)
or the timer times-out
after the dwell period (‘
DwEll’)
. It is typically use
to dry-out heaters in Hot Runner control systems
TIMER RUNNING
TIMER END
Run
RESET Digital input
Temp
Setpoint
Time
Time
Soft Start power limit SS.PWR
Soft start setpoint
SS.SP
RUN
END
Reset