100 MM GRAPHICS RECORDER: USER GUIDE
User Guide
Page 119
HA027271
Issue 12 Mar 04
Apply
Discard
Archive to Media
On Media Full
Compression
None
Media Size
1.38
Mb
Overwrite
Normal
Flash Size
2 . 7 5
Mb
Disk Archive Capacity
3 . 5 7
Days
Shortest Trend History
G r o u p 1
Select: Overwrite or Stop
Select: Normal or High
Show
Disk settings
Select 'Disk' or
'Remote' settings
Duration
7 . 2 8
Days
Media Full event limit
100
%
Select: Archive interval
Media File Format
Binary
Appears only if CSV option is fitted
Archive to Remote
None
Select archive interval
Remote path
Show
Remote settings
0.0.0.0
Primary remote host
Primary login name
a n o n y m o u s
Primary password
* * * * *
Retype password
* * * * *
0.0.0.0
Secondary remote host
Secondary login name
a n o n y m o u s
Secondary password
* * * * *
Retype password
* * * * *
/ r e c o r d e r / G r o u p 1
Compression
Normal
Flash Size
2 . 7 5
Mb
Shortest Trend History
G r o u p 1
Select: Normal or High
Duration
8 . 7 1
Days
Ftp File format
Binary
Appears only if CSV option fitted
Apply
Discard
Instrument Name
Normal Display
Saver Display
Instrument
Save After
100
1
%
%
Minutes
Modbus Security Disabled
Comms Channel Timeout
s
50
0
= Disabled
Preset Hour
12
Preset Minute
0
Apply
Discard
Modbus Address
1
Apply
Discard
Select event 1 to 6 for configuration
Event Number
1) Event 1
Source 1
Descriptor
Event 1
Select: 1 or 2
Job Number
1
Category
No Action
Select Job Category
Alarm on Group
Select source 1
On Group
1) Group 1
Source 2
Point Alarm
Select source 2
On
Math 12
Alarm
2
Source 1 Sense
Operator
Source 2 Sense
Source 1
And
Not Source 2
Make sub-sub selection (if any)
Select logic combination: Only, AND,
OR, NAND, NOR, XOR.
Select source inversion or not
Select source inversion or not
Make source 1 sub selection (if any)
Make source 2 sub selection (if any)
Apply
Discard
Alarm Message
Ack Message
TurbineTempA
TurbineTempB
TurbineTempC
= Enabled
Etc.
Recording Speed
Recording Interval
1
1,200
mm/hr
s
Archive to Media Enable
Archive via FTP Enable
List of all available points
(input channels, maths chan-
nels, totalisers etc.).
Trend History Duration
25.96
Days
Select mm/hr or in/hr
Trend Units
mm/hr
Descriptor
Trend Speed
Trend Interval
1
1,200
mm/hr
s
Group 1
Group Number
1) Group 1
Select Group
Recording Enable
Appear only if
'Recording Enable'
is enabled.
Grid Type
From Point
Select None. Linear, Log (if
option fitted) or 'From Point'.
from
Channel 1
Field(s) vary with selected
Grid Type
A/B Switching
User Linearisation
Descriptor
Format
Number of Points
X1
Y1
X2
3) UserLin3
Numeric
2
0
0
1
Apply
Discard
Y2
1
UserLin3
Select Numeric
or Scientific
Remote
Config\Archive
(Section 4.3.5)
Disk
See figure B8b
See figure B8d
Archive
System
Save/R.. Config
Security Network
Config\Groups (Section 4.3.2)
Config\Events (Section 4.3.6)
Config\Instrument
(Section 4.3.1)
Select Home
display mode for
instrument or for
selected group
= Enabled
Home Time-out
Home Group
Dark Trend Background
Dark Review Background
Scope
Group
Display enable
Home Page
Vertical Trend
Horizontal Trend
Vertical Bargraph
Horizontal Bargraph
Numeric Page
1) Group 1
Apply
Discard
0
Group
1) Group 1
Horizontal Bargraph
Select group for
Home display
Select group for
display mode enable
Select Instrument or Group
Minutes
Config\Views (Section 4.3.4)
For further menu items -
see figure B8f
Message Number
Message
Replace {1} with
Replace {2} with
Replace {3} with
{3} source
Replace {4} with
{4} source
Replace {5} with
Apply
Discard
Select:
Source Descriptor,
Source Value,
Specified Descriptor,
Specified Value or
Blank
Replace {6} with
1) The value of
The value of {1} = {2} & {3} = {4}
Source Descriptor
Source Value
Totaliser 1
Specified Descriptor
Totaliser 1
Specified Value
Blank
Blank
Select:
Channel/totaliser etc.
whose descriptor/value
is to be inserted
Select Message 1 to 12
for configuration
Config\Messages (Section 4.3.7)
See
figure B8e
User Linearisations
(Section 4.3.8)
Channels (Section 4.3.3)
Apply
Discard
Job Number
1
Category
No Action
Select: 1 or 2
Select: Job category
Value
5.0002
Input Type
Thermocouple
Select Linearisation
type (e.g.Type K)
Lin Type
Type K
Off, T/C, mV,V, mA,
RTD, Ohms, Digital,
Comms or Test
Range Low
0
C
Range High
1
C
Range Units
C
Scaled
Scale Low
0
V
Scale High
1
V
Select: Celsius, Fahrenheit,
Kelvins or Rankine
Units
V
Offset
0
V
Filter
None
Select: None, 2, 4, 8, 16, 32,
64, 128 or 256 seconds
Break Response
None
Select Alarm number
Cold Junction Type
Off
Descriptor
TurbineTempA
Select: Off, Internal,
External or Remote
Spanned A
Span Low A
0
V
Span High A
1
V
Zone Low A
0
%
Zone High A
100
%
Max Decimal Digits
4
Colour
Alarm Number
1
Enable
Unlatched
Select Off, Unlatched, Latched or Trigger
26
Select: None, High or Low
Channel Number
1) TurbineTempA
Select channel number
18/04/01 15:17:10
Type
Absolute Low
Select Absolute,
Deviation or Rate-of-change
Threshold
Hysteresis
Dwell
0
V
0
V
0
s
These fields vary according to
Alarm Type selection
Scale Type
Scale Divisions - Major
10
1
Scale Divisions - Minor
Linear
Select None, linear or (if option fitted),
Log
These fields vary according to
Scale Type selection
PV Format
Numeric
Select Numeric or Scientific
A/B Switching
Spanned B
Zone Low B
0
%
Zone High B
100
%
Instrument
Groups
Channels
Views
Archive
Events
Messages
User Linearisations
B8 MENU STRUCTURE (Cont.)
Figure B8c Menu structure sheet 3 (Config key)